1997
DOI: 10.1117/12.268963
|View full text |Cite
|
Sign up to set email alerts
|

Study of an algorithm based on model experiments and diffusion theory for a portable tissue oximeter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
57
0

Year Published

1998
1998
2015
2015

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 76 publications
(58 citation statements)
references
References 24 publications
1
57
0
Order By: Relevance
“…In NIRS, THb/Mb, Hb/MbO 2 and deoxy hemoglobin and myoglobin (HHb/Mb) are obtained by the following equations (24).…”
Section: Discussionmentioning
confidence: 99%
“…In NIRS, THb/Mb, Hb/MbO 2 and deoxy hemoglobin and myoglobin (HHb/Mb) are obtained by the following equations (24).…”
Section: Discussionmentioning
confidence: 99%
“…Realistic situations are particularly valuable when exploring human executive functions and fiberless fNIRS systems may provide a unique insight into human brain functions. The first fiberless systems were equipped only with a small number of channels (e.g., single channel 15 and 2 channels 16 ) limiting the investigation to small areas. More recently, multichannel wireless and wearable fNIRS devices have been developed 6,7,[17][18][19][20] giving the possibility to monitor larger portions of the head on freely moving participants.…”
Section: Introductionmentioning
confidence: 99%
“…The light can penetrate soft tissue up to approximately 2.0 cm when the detector is at a distance of 4 cm from the radiation source. Relative changes in oxygenated haemoglobin (oxy-Hb), deoxygenated Hb (deoxy-Hb), and total Hb (t-Hb) were calculated by the equation reported in a previous study (Shiga et al, 1997). However, continuous wave NIRS could not provide absolute values because of unknown physical properties such as the optical path length in tissue (Hamaoka et al, 2007;McCully & Hamaoka, 2000).…”
Section: The Difference Of Acupuncture On Autonomic System and Localimentioning
confidence: 99%
“…The light can penetrate soft tissue up to approximately 2.0 cm when the detector is at a distance of 4 cm from the radiation source. Relative changes in oxygenated haemoglobin (oxy-Hb), deoxygenated Hb (deoxy-Hb), and total Hb (t-Hb) were calculated by the equation reported in a previous study (Shiga et al, 1997). Corrected concentrations (mM) considering the subcutaneous adipose tissue thickness (ATT) for oxy-Hb, deoxy-Hb, and t-Hb were obtained by dividing the concentrations with normalized measurement sensitivity S as shown in the literature (Niwayama et al, 2002).…”
Section: The Effect Of Varying Acupuncture Techniques On Muscle Bloodmentioning
confidence: 99%