2016
DOI: 10.1080/10826076.2016.1141364
|View full text |Cite
|
Sign up to set email alerts
|

Studies on the sorption behavior of quercetin, phenol, and caffeine as test substances on diol mixed-mode HILIC column

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

6
13
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(19 citation statements)
references
References 33 publications
6
13
0
Order By: Relevance
“…Similar adsorption behavior can be also found in systems with diol‐type polar stationary phase (Dionex/Thermo Scientific Acclaim® Mixed‐Mode HILIC‐1 column, 150 × 4.6 mm, 5 μm particle size, 120 Å pore size and 300 m 2 /g surface area) [12]. The AEDs of Q and PH for ACN–water and MeOH–water mobile phases (containing both 70% v/v and 90% v/v of organic solvent) presented in work [12] were found to be bimodal with the main role of low‐energy active sites (type 1). The higher energy interactions (type 2) have in these systems much smaller capacity, q s2 .…”
Section: Resultsmentioning
confidence: 53%
See 3 more Smart Citations
“…Similar adsorption behavior can be also found in systems with diol‐type polar stationary phase (Dionex/Thermo Scientific Acclaim® Mixed‐Mode HILIC‐1 column, 150 × 4.6 mm, 5 μm particle size, 120 Å pore size and 300 m 2 /g surface area) [12]. The AEDs of Q and PH for ACN–water and MeOH–water mobile phases (containing both 70% v/v and 90% v/v of organic solvent) presented in work [12] were found to be bimodal with the main role of low‐energy active sites (type 1). The higher energy interactions (type 2) have in these systems much smaller capacity, q s2 .…”
Section: Resultsmentioning
confidence: 53%
“…In these systems, the AEDs were found to be bimodal and quantitatively very similar as for Q and PH (i.e. the major part of the global adsorption capacity, q s , of the column is due to the sites of type 1 and the sites of type 2 have a smaller capacity) [12]. Regardless of some differences, the obtained results indicate that despite the presence of heterogeneous AEDs in the studied systems, the main role in the adsorption/retention mechanism in amine, amide, zwitterionic, and also diol type adsorbents is played by low‐energy active sites.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…To systemically investigate the retention behavior of quercetin, phenol, caffeine on diol Acclaim Mixed Mode HILIC column, three aspects were considered: temperature investigation with van't Hoff plots, column efficiency under different MP systems calculated by van Deemter plots, and adsorption study analyzed by frontal analysis combined with adsorption energy distributions . The temperature investigations showed that except for some systems containing quercetin, the global adsorption behavior was exothermic.…”
Section: Retention Mechanism and Retention Behavior In Hilicmentioning
confidence: 99%