1978
DOI: 10.3109/17453677808993229
|View full text |Cite
|
Sign up to set email alerts
|

Studies on Mechanical Strength of Bone:I. Torsional Strength of Normal Rabbit Tibio-Fibular Bone

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
1

Year Published

1978
1978
2018
2018

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 30 publications
(19 citation statements)
references
References 21 publications
0
18
1
Order By: Relevance
“…A s reported earlier (Paavolainen 1978), the mechanical properties of the rabbit tibio-fibular bone, apart from angular deformation, are energy absorbed until fracture (Nm) critically dependent on the body weight of the animal. Hence, the data obtained for each bone specimen were corrected for the weight of the animal.…”
Section: Calculationsmentioning
confidence: 99%
See 1 more Smart Citation
“…A s reported earlier (Paavolainen 1978), the mechanical properties of the rabbit tibio-fibular bone, apart from angular deformation, are energy absorbed until fracture (Nm) critically dependent on the body weight of the animal. Hence, the data obtained for each bone specimen were corrected for the weight of the animal.…”
Section: Calculationsmentioning
confidence: 99%
“…As previously described (Paavolainen 1978), the ends of the bones were embedded in nuts with epoxy resin, leaving a constant length (8.5 cm) of bone for testing. The specimen was then fitted into the sockets of the torsiometer and subjected to external rotation at a constant deformation speed of 3.6 degreedsecond.…”
Section: Testing Of the Mechanical Propertiesmentioning
confidence: 99%
“…Biphasic changes in the biomechanical strength of healing osteotomies have been reported from this laboratory after rigid plate fixation (Paavolainen et al 1979). The similarity in bone strength alterations after rigid intramedullary nailing and rigid plate fixation is obvious (Figure 1).…”
Section: Discussionmentioning
confidence: 62%
“…The load-deformation curves were simultaneously recorded. Each bone was photographed before and after testing, and the type of fracture was recorded (Paavolainen 1978).…”
Section: Methodsmentioning
confidence: 99%
“…The specimen was subjected to torsion at a constant angular velocity of 3.6 degreedsecond. The precision of the testing equipment has been reported by Paavolainen (1978).…”
Section: Mechanical Testsmentioning
confidence: 99%