Studies of polymerization of acrylic monomers using luminescence probes and differential scanning calorimetry

Abstract: A fiber optic system has been designed to couple calorimeter and fluorimeter equipment for in situ monitoring of polymerization reactions by both techniques simultaneously. Two acrylic monomers (cyclohexyl methacrylate, CHM, and 2-ethylhexyl acrylate, EHA) were studied at different temperatures. Pyrene (Py) was employed at a low concentration (:Sl0-4 mol/L) as a fluorescence probe. The emission spectrum of pyrene shows a broad band peaking at 390 nm, whose intensity grows with polymerization progress. A correl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2002
2002
2013
2013

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(22 citation statements)
references
References 17 publications
0
22
0
Order By: Relevance
“…The kinetics of the photoinitiated polymerization of acrylates and methacrylates has been studied by means of photo differential scanning calorimetry (photoDSC) [17][18][19][20][21][22][23], real time Fourier transform infrared analysis (FT-IR) [18,[24][25][26], photorheology [27,28], and fluorescent probe [29,30]. The autocatalytic model has been widely employed to describe the photopolymerization kinetics [17,20,30,31].…”
Section: Introductionmentioning
confidence: 99%
“…The kinetics of the photoinitiated polymerization of acrylates and methacrylates has been studied by means of photo differential scanning calorimetry (photoDSC) [17][18][19][20][21][22][23], real time Fourier transform infrared analysis (FT-IR) [18,[24][25][26], photorheology [27,28], and fluorescent probe [29,30]. The autocatalytic model has been widely employed to describe the photopolymerization kinetics [17,20,30,31].…”
Section: Introductionmentioning
confidence: 99%
“…After mixing, the sample was placed on a preheated sample cell composed of two glass slides and a Teflon spacer (0.5 mm). Epoxy conversion, R, was determined following the extinction of the epoxy band (4532 cm -1 ) referred to a reference C φ-H band (4623 cm -1 ), according to the following expression, where S is the integrated absorbance of the band A built-in optical device 25 was used for measuring the cloud point. It consisted of an optical fiber coupling between a Fluorimeter (Perkin-Elmer LS50B) and a calorimeter (PerkinElmer DSC7).…”
Section: Methodsmentioning
confidence: 99%
“…Fluorescence is a very sensitive and non-destructive technique to monitor curing of different polymeric systems [15][16][17][18][19][20][21][22][23][24]. The use of fluorescen response from labels and probes has become a very powerful tool to follow changes in its surroundings such as polarity and/or rigidity [15][16][17][18][19][20][21][22][23][24][25][26][27].…”
Section: Introductionmentioning
confidence: 99%
“…The use of fluorescen response from labels and probes has become a very powerful tool to follow changes in its surroundings such as polarity and/or rigidity [15][16][17][18][19][20][21][22][23][24][25][26][27]. Some works propose that an enhancement in the microviscosity of the medium leads to a decrease in the non-radiative decay rate and consequently an increase in the fluorescenc quantum yield [19].…”
Section: Introductionmentioning
confidence: 99%