1989
DOI: 10.1007/bf01701936
|View full text |Cite
|
Sign up to set email alerts
|

Structure-toxicity relationships for mono alkyl- or halogen-substituted anilines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

1992
1992
2003
2003

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 18 publications
(6 citation statements)
references
References 7 publications
0
6
0
Order By: Relevance
“…From the original set of 93 chemicals common to both test systems, four compounds were not toxic at amounts that saturate the protozoan growth media and were excluded from further analyses. Previous studies [20,21] have noted that para-position halogen-substituted anilines are excessively toxic in the Tetrahymena assay. Seven of these anilines were removed from the data set in further analyses, as no explanation can be made at this time for their toxicity.…”
Section: Resultsmentioning
confidence: 90%
“…From the original set of 93 chemicals common to both test systems, four compounds were not toxic at amounts that saturate the protozoan growth media and were excluded from further analyses. Previous studies [20,21] have noted that para-position halogen-substituted anilines are excessively toxic in the Tetrahymena assay. Seven of these anilines were removed from the data set in further analyses, as no explanation can be made at this time for their toxicity.…”
Section: Resultsmentioning
confidence: 90%
“…On the basis of these preliminary evaluations, it was decided to examine all relationships between physicochemical properties and acute local effects separately for lesions on skin and for lesions on eyes and, in addition, to examine relationships between n-octanol/ water partition coefficient and local irritation/corrosion, because this parameter correlating hydrophilic and hydrophobic substance properties has proved to be predictive for ecotoxicokinetic substance properties (12)(13)(14)(15)(16)(17)(18), and thus may also be predictive for specific local toxic effects (11,19,20). It was also decided to examine the relationship between surface tension and local irritation/corrosion, because surface activity alters the effects of aqueous solubility and lipid solubility on the capacity of a chemical to penetrate membranes.…”
Section: Calculation Of Sar Algorithms: Evaluation Of Physical Datamentioning
confidence: 99%
“…The logarithm of the octanol/water partition coefficient (log P ow ) for the partition of a chemical between a hydrophilic solvent phase (water) and a hydrophobic solvent phase (n-octanol) is correlated with the aqueous solubility (21). Log P ow has proved to be a good parameter for considerations relating to the possible kinetic fate of a chemical in the environment, and as represented by percutaneous absorption of chemicals from natural waters, from ambient air, and from soil (12)(13)(14)(15)(16)(17)(18). SAR considerations relating to local irritation/corrosion can also be based on this partition coefficient (11,19,20).…”
Section: Relationships Between Octanol/water Partition Coefficient Anmentioning
confidence: 99%
“…From the original set of 93 chemicals common to both test systems, four compounds were not toxic at amounts that saturate the protozoan growth media and were excluded from further analyses. Previous studies [20,21] have noted that para‐position halogen‐substituted anilines are excessively toxic in the Tetrahymena assay. Seven of these anilines were removed from the data set in further analyses, as no explanation can be made at this time for their toxicity.…”
Section: Resultsmentioning
confidence: 99%