2010
DOI: 10.1016/j.jcat.2010.02.009
|View full text |Cite
|
Sign up to set email alerts
|

Structure and properties of a Mo oxide catalyst supported on hollow carbon nanofibers in selective propene oxidation

Abstract: In situ X-ray absorption spectroscopy (XAS) under reaction conditions of selective propene oxidation was employed to elucidate the local structure of as-prepared and activated molybdenum oxide supported on hollow vapor-grown carbon nanofibers (VGCNF). The local structure of asprepared MoxOy-VGCNF was very similar to that of hexagonal MoO3. During heat treatment in propene-and oxygen-containing atmosphere, asprepared MoxOy-VGCNF transforms into activated MoxOy-VGCNF above 623 K. The local structure around the M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
1

Year Published

2011
2011
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 29 publications
(13 citation statements)
references
References 25 publications
0
12
0
1
Order By: Relevance
“…The accuracy of the mean bond length R and coordination numbers ( CN s), including systematic errors, for the S shells are within 0.02 Å and 20 %, respectively 2223. Confidence limits of adjusted parameters (precision), as calculated from a variation of the fit residual ( Res ) within 95 % of its optimal value19c are, however, generally at least two times better.…”
Section: Methodsmentioning
confidence: 86%
“…The accuracy of the mean bond length R and coordination numbers ( CN s), including systematic errors, for the S shells are within 0.02 Å and 20 %, respectively 2223. Confidence limits of adjusted parameters (precision), as calculated from a variation of the fit residual ( Res ) within 95 % of its optimal value19c are, however, generally at least two times better.…”
Section: Methodsmentioning
confidence: 86%
“…The amplitude reduction factor, S 0 , was fixed to 0.85 from the EXAFS analysis of Hg­(SEt) 2 and Hg­(SPh) 3 . The accuracy of the mean bond distance R and coordination numbers (CNs), including systematic errors, for the S shells are within 0.02 Å and 20%, respectively. , Confidence limits of adjusted parameters (precision), as calculated from a variation of the fit residual (Res) within 95% of its optimal value, are, however, typically 2 times better.…”
Section: Methodsmentioning
confidence: 99%
“…Logam lainnya seperti NiOdapat digunakan sebagai katalis (Ressler et al, 2010). Kobal oksida memiliki beberapa jenis oksida seperti CoO, Co2O3 dan Co3O4, yang memiliki sifat dan karakteristik bebeda.…”
Section: Pendahuluanunclassified