2014
DOI: 10.1007/s10518-014-9660-7
|View full text |Cite
|
Sign up to set email alerts
|

Structural damage in the cities of Reggiolo and Carpi after the earthquake on May 2012 in Emilia Romagna

Abstract: This paper addresses the structural damage to the main buildings of the cities of Reggiolo and Carpi after the primary earthquake shocks on May 20th and 29th, 2012, in Emilia Romagna. The damage survey, performed via form-based methods, highlights the different seismic behaviour of several types of buildings, especially those having historical\ud features, and the consequences of the damage in terms of costs.Moreover, an analysis of some failure mechanisms activated in Reggiolo enables the evaluation of the lo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
8
1

Relationship

6
3

Authors

Journals

citations
Cited by 33 publications
(19 citation statements)
references
References 20 publications
0
19
0
Order By: Relevance
“…Despite having a moderate magnitude of 5.1 Mw, the quake on 11 May 2011 caused important casualties (9 people died and more than 300 were injured) and important structural damage which forced more than 10,000 people to be evacuated from their homes during the first days [36]. Considering the comparatively small size of the city of Lorca and the homogenous results that the seismic event produced in the urban area, the quake was defined with an EMS-98 macroseismic intensity (I EMS-98 ) of VII [37] in the main neighborhoods of the city.…”
Section: Application Of the Risk-ue Lm1 Methods For Seismic Vulnerabilmentioning
confidence: 99%
See 1 more Smart Citation
“…Despite having a moderate magnitude of 5.1 Mw, the quake on 11 May 2011 caused important casualties (9 people died and more than 300 were injured) and important structural damage which forced more than 10,000 people to be evacuated from their homes during the first days [36]. Considering the comparatively small size of the city of Lorca and the homogenous results that the seismic event produced in the urban area, the quake was defined with an EMS-98 macroseismic intensity (I EMS-98 ) of VII [37] in the main neighborhoods of the city.…”
Section: Application Of the Risk-ue Lm1 Methods For Seismic Vulnerabilmentioning
confidence: 99%
“…Damage in small constructions with cracks in masonry infill walls at the ground floor and failures at the end of columns is generally identified in this type of buildings due to their higher stiffness [5,35,36]. Thus, the behavior lower height building is penalized with a value of 0.04, whose natural frequency coincides with the amplified area of constant spectral acceleration, and the vulnerability of the highest buildings is diminished (−0.04) coinciding with the spectrum area of decreasing accelerations.…”
Section: Modifier Of Behavior Level Of Design Codementioning
confidence: 99%
“…In other contexts the presence of humidity at the base of the walls is able to reduce the mechanical properties and the integrity of the constructions [3]. In these last cases, the application of specific reinforced damp proof courses [4] or temporary reinforcements [5] can mitigate this aspect.…”
Section: Introductionmentioning
confidence: 99%
“…columns, and inadequate bonded lengths and overlapping of bars. All these deficiencies in structural details may cause the local brittle shear mechanism and global collapse mechanism of "weak columns" [37,38].…”
Section: Description Of the Buildingsmentioning
confidence: 99%