2021
DOI: 10.1016/j.ejps.2020.105689
|View full text |Cite
|
Sign up to set email alerts
|

Structural characterization and developability assessment of sustained release hydrogels for rapid implementation during preclinical studies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 79 publications
0
8
0
Order By: Relevance
“…According to the literature, the observed drug release from PCLA thermosensitive hydrogels was controlled and prolonged for up to 30 days. In general, the release kinetics were close to first order, and matrix decomposition was observed during the experiments [ 3 , 64 ]. Li and coworkers [ 23 ] obtained the PCLA hydrogel as injectable flurbiprofen DDS.…”
Section: Resultsmentioning
confidence: 97%
See 2 more Smart Citations
“…According to the literature, the observed drug release from PCLA thermosensitive hydrogels was controlled and prolonged for up to 30 days. In general, the release kinetics were close to first order, and matrix decomposition was observed during the experiments [ 3 , 64 ]. Li and coworkers [ 23 ] obtained the PCLA hydrogel as injectable flurbiprofen DDS.…”
Section: Resultsmentioning
confidence: 97%
“…Among the most promising types of DDSs are hydrogels—3D, crosslinked polymeric structures capable of absorbing large amounts of water or biological fluids while retaining integrity [ 2 ]. The primary benefits of using hydrogels as drug carriers include ease of manufacturing and administration, the ability to deliver a variety of drugs, and nearly 100% drug entrapment [ 3 ]. Stimuli-sensitive hydrogels, also known as smart hydrogels, can change their properties in response to external or internal stimuli such as temperature, pH, ionic strength, electromagnetic radiation, magnetic field, or biological factors (antibodies or enzymes) [ 2 , 4 , 5 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…When performing injection force measurements, there was an initial increase in force during start up, and then the force plateaued (Figure S16). The initial increase in force is attributed to friction during start up, whereas the plateau is characterized as a “glide force” representative of the material being injected . The injection force reported below is the plateau force over a 10 s interval.…”
Section: Resultsmentioning
confidence: 99%
“…The initial increase in force is attributed to friction during start up, 74 whereas the plateau is characterized as a "glide force" representative of the material being injected. 75 The injection force reported below is the plateau force over a 10 s interval. For a given cross-linking chemistry, an increase in a hydrogel's polymeric concentration resulted in an increased injection force (Figure 6b).…”
Section: ■ Materials and Methodsmentioning
confidence: 99%