“…Often the fracture or stretching of bolts, or the stripping or loosening of nuts, is the first visible sign that there is a fatigue problem caused by vibration. Any occurrence of a failure of several bolts in a chimney should prompt an investigation of vibration [3,12]. Vortex suppression devices such as shrouds, helical strakes, spoiling plates and vertical vanes or damping devices should be fitted to stack to minimize the VIVs and to increase fatigue life [5,13,14].…”
Section: Measures To Reduce Fatiguementioning
confidence: 99%
“…Often the fracture or stretching of bolts, or the stripping or loosening of nuts, is the first visible sign that there is a fatigue problem caused by vibration. Any occurrence of a failure of several bolts in a chimney should prompt an investigation of vibration [3,12]. Vortex suppression devices such as shrouds, helical strakes, spoiling plates and vertical vanes or damping devices should be fitted to stack to minimize the VIVs and to increase fatigue life [5,13,14].…”
Section: Measures To Reduce Fatiguementioning
confidence: 99%
“…With the collected behavior data, fatigue calculations were made based on the Eurocode and were compared with the constant amplitude method. Tranvik and Alpsten [81] investigated the structural behavior of a 90 m high steel chimney and summarized the results collected from approximately four years of continuous measurements and regular observations of the chimney. The obtained data have some general relevance with respect to wind data, behavior of a slender structure under wind loading, and the effects of a mechanical damper.…”
Section: Full-scale Measurementsmentioning