2018
DOI: 10.1016/j.compstruct.2018.07.109
|View full text |Cite
|
Sign up to set email alerts
|

Structural applications of fibre reinforced polymer (FRP) composite tubes: A review of columns members

Abstract: Use of fibre reinforced polymer (FRP) in column applications is increased because it can act as a confining material, a reinforcement and a structural column. The application of FRP tubes is correlated with the fibre orientation since tube stiffness is mainly attributed to the stiffness of fibres. Thus, for confinement, the fibres should align in the transverse direction of the tube while they should align in the axial direction when tubes are used as compression members. FRP tubes with fibres mainly in axial … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 65 publications
(16 citation statements)
references
References 79 publications
0
16
0
Order By: Relevance
“…Otherwise, insufficient lateral details result in premature elastic buckling of the longitudinal bars and a sudden loss in load-carrying capacity [71]. Because of this, plain-concrete HCCs encased within outer and inner steel or FRP tubes are currently being used to increase the strength performance of HCCs and to overcome the brittle behavior related to the thin concrete wall [67]. These approaches, however, are difficult to implement and not cost-effective.…”
Section: Brittle Failure Behavior Of Steel-reinforced Hccsmentioning
confidence: 99%
“…Otherwise, insufficient lateral details result in premature elastic buckling of the longitudinal bars and a sudden loss in load-carrying capacity [71]. Because of this, plain-concrete HCCs encased within outer and inner steel or FRP tubes are currently being used to increase the strength performance of HCCs and to overcome the brittle behavior related to the thin concrete wall [67]. These approaches, however, are difficult to implement and not cost-effective.…”
Section: Brittle Failure Behavior Of Steel-reinforced Hccsmentioning
confidence: 99%
“…FRPs also have the potential to strengthen the existing structural elements and reduce the amount of reinforcement and cementitious materials in concrete [39][40][41][42]. In recent years, some structural (i.e., walls, beams, columns, and slabs) and nonstructural (i.e., facades and curtain walls) elements in the buildings have been fabricated with FRPs [43][44][45]. Figure 2(b) shows some examples in which FRPs are used to construct facades of new buildings.…”
Section: Prefabricated Polymer Elementsmentioning
confidence: 99%
“…In a concrete-filled FRP tubular (CFFT) column, the axial bearing contribution of the outer FRP tube to the total load carried by the composite column would be very limited if the fibers are mainly oriented in the hoop direction. In fact, the compressive strength of an FRP tube in the orthogonal direction to the reinforcing fibers is mainly dependent on its resin matrix [45]. Therefore, the axial contribution of such FRP tube to a CFFT column is usually omitted during the calculation process.…”
Section: Axial Load Vs Strain Responsementioning
confidence: 99%