2003
DOI: 10.1016/s0921-4526(03)00081-4
|View full text |Cite
|
Sign up to set email alerts
|

Structural and calorimetric studies of mixed K2MoxW(1−x)O4 (0⩽x⩽1) compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
6
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 11 publications
1
6
0
Order By: Relevance
“…[87] Use of the optimised MoÀO bond distance increases the agreement with the spectroscopic measurements. Variations of the O-Mo-O angles in the MoO 4 tetrahedra are less than 28.…”
Section: Effects Of Structural Optimisation On the Calculations Of Qumentioning
confidence: 80%
See 1 more Smart Citation
“…[87] Use of the optimised MoÀO bond distance increases the agreement with the spectroscopic measurements. Variations of the O-Mo-O angles in the MoO 4 tetrahedra are less than 28.…”
Section: Effects Of Structural Optimisation On the Calculations Of Qumentioning
confidence: 80%
“…Herein, we present calculations of EFG and CS tensors using PAW and GIPAW methods for a set of ternary molybdates of general formula AMoO 4 , where A is a divalent cation (Ba, [81] Pb, [82] Ca, [83] Sr, [84] Cd, [85] Zn [86] ), and A' 2 MoO 4 , where A' is a monovalent cation (K, [87] Cs, [88] Rb, [89] Na, [90] NH 4 [91] ). In all these compounds, molybdenum atoms have a + VI formal oxidation state and are coordinated to four oxygen atoms in a nearly tetrahedral symmetry (see Figure 1).…”
Section: Introductionmentioning
confidence: 99%
“…9,15 Several attempts to grow untwinned crystals suitable for single-crystal experiments failed so powder samples have to be used for the x-ray diffraction analysis. Due to the high hygroscopic character of the compounds the samples were handled on a nitrogen-atmosphere glove box where they were crushed into fine powders, and then placed into glass capillaries of 0.4 and 0.5 mm in diameter.…”
Section: Methodsmentioning
confidence: 99%
“…The absolute temperatures of the corresponding phase transitions were taken from differential scanning calorimetry experiments. 9,15,16 Accordingly, the temperature ranges for the modulated phase are 640͑5͒-734͑5͒ K, 601͑5͒-727͑5͒ K, and 593͑5͒-730͑5͒ K for K 2 WO 4 , K 2 Mo 0.5 W 0.5 O 4 , and K 2 MoO 4 , respectively.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation