2017
DOI: 10.1016/j.fusengdes.2017.02.062
|View full text |Cite
|
Sign up to set email alerts
|

Structural analysis of DEMO divertor cassette body and design study based on RCC-MRx

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 8 publications
(17 reference statements)
1
7
0
Order By: Relevance
“…As obtained previously [4][5], the thermal loads play a relevant role: indeed in the fig. 5 there are the Nose (left), the cassette (center) and the knuckle pins (right) equivalent stresses: it can be seen that the stress level either of the Nose or the knuckle pins is relevant (350 -500 MPa).…”
Section: Thermal Loadssupporting
confidence: 75%
See 3 more Smart Citations
“…As obtained previously [4][5], the thermal loads play a relevant role: indeed in the fig. 5 there are the Nose (left), the cassette (center) and the knuckle pins (right) equivalent stresses: it can be seen that the stress level either of the Nose or the knuckle pins is relevant (350 -500 MPa).…”
Section: Thermal Loadssupporting
confidence: 75%
“…This set of data has been adopted for the coupledfield thermal-fluid dynamic analysis reported in [11][12]. Unlike from the previous works [4][5], the thermal power has been applied exactly the same: so the temperature gradients have been simulated in a more realistic manner (and more adequate for the structural analysis purposes): in fig. 3 there is the obtained temperature contour plot.…”
Section: Thermal Loads Inputmentioning
confidence: 99%
See 2 more Smart Citations
“… New interfaces with breeding blanket and vacuum vessel  Inlet cooling water at 3.5 MPa -180°C  The PFCs cooling system configuration selected during the first pre-concept design phase [3] to be integrated in the new cassette shape  Eurofer97 material for divertor cassette: ribs thickness 20 mm; external plate thickness 30 mm (considering the stress analyses performed in the first phase [6]). (Fig.…”
Section: Demo Divertor Cassette Body Designmentioning
confidence: 99%