Order By: Relevance
“…Hence, the Von Mises stress failure criterion is adopted in this work. Because the hyper-elastic models in Abaqus/Explicit do not incorporate the material failure mechanism, a special user material subroutine with a Von Mises stress failure criterion is put forward [ 57 ]. When the effective stress of the unit near the MN tip meets the failure criteria shown in (2) , the unit will be identified and removed from the grid [ 46 , 58 ].…”
Section: Methodsmentioning
confidence: 99%
“…Hence, the Von Mises stress failure criterion is adopted in this work. Because the hyper-elastic models in Abaqus/Explicit do not incorporate the material failure mechanism, a special user material subroutine with a Von Mises stress failure criterion is put forward [ 57 ]. When the effective stress of the unit near the MN tip meets the failure criteria shown in (2) , the unit will be identified and removed from the grid [ 46 , 58 ].…”
Section: Methodsmentioning
confidence: 99%
“…Generally, the filling mould methods mainly include centrifugation or vacuum [ 126 ]. Lithography, as a print process, transfers the master pattern of the MNs geometry to the surface of the substrate without any moulds [ 127 ]. The novel technique could use 3D printing and centrifugal lithography [ 125 , 128 ].…”
Section: Challenges In Scale Manufacture and Regulations Of Polymeric...mentioning
confidence: 99%
“…A micron-scale needle, also known as a microneedle (MN), 1,2 is a minimally invasive needle used for injection, 3,4 dermal and transdermal delivery of drugs, 5−8 biological substances, 9 skin care therapy, 10,11 and monitoring glucose levels 10 through extraction of a special fluid known as interstitial fluid (ISF). 5,12 MNs have been a substitute of hypodermic needles due to their rapid painless procedure, 11,13−15 affordable fabrication methods, 9 reduced tissue rupturing, and self-handle and compact administration. 11 Their capabilities of penetrating the skin layer with the goal of transferring proteins, 9 DNA, 9,14 and vaccines 9,14,16,17 in the most efficient and minimally invasive manner make MNs a promising technology for various medical applications.…”
Section: ■ Introductionmentioning
confidence: 99%
“…5,12 MNs have been a substitute of hypodermic needles due to their rapid painless procedure, 11,13−15 affordable fabrication methods, 9 reduced tissue rupturing, and self-handle and compact administration. 11 Their capabilities of penetrating the skin layer with the goal of transferring proteins, 9 DNA, 9,14 and vaccines 9,14,16,17 in the most efficient and minimally invasive manner make MNs a promising technology for various medical applications. 11,18,19 Moreover, researchers show that MNs can be incorporated with diagnostic capabilities to assess diseases based on painless experience and monitoring the health condition by means of invasive and noninvasive methods.…”
Section: ■ Introductionmentioning
confidence: 99%