2023
DOI: 10.1109/led.2023.3240764
|View full text |Cite
|
Sign up to set email alerts
|

Stretchable Iontronic Pressure Sensor Array With Low Crosstalk and High Sensitivity for Epidermal Monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 16 publications
(12 citation statements)
references
References 33 publications
0
8
0
Order By: Relevance
“…Evaluation by understanding the precision and interpretation of the multimodal field data produced by the system. According to [44], it will be challenging to employ multiple sensors in the same location. As a result of intersensor "crosstalk".…”
Section: The Stage Of Data Review Produced By the Monitoring Systemmentioning
confidence: 99%
“…Evaluation by understanding the precision and interpretation of the multimodal field data produced by the system. According to [44], it will be challenging to employ multiple sensors in the same location. As a result of intersensor "crosstalk".…”
Section: The Stage Of Data Review Produced By the Monitoring Systemmentioning
confidence: 99%
“…Epidermal Dielectric Layer (EDL) capacitive sensors exhibit remarkable sensitivity, a large span, and a short response time, making them an ideal solution for epidermal electronics [ 117 , 118 ]. These sensors have the ability to detect force and human muscle movement and adhere to human skin, thereby providing a versatile platform for various diagnostic applications in healthcare.…”
Section: Applications Of Epidermal Electronics In Diagnosis and Thera...mentioning
confidence: 99%
“…Zheng et al [ 205 ] proposed a low-crosstalk stretchable ionization sensing array for wrist pulse measurement, as shown in Figure 8 B, which achieves excellent performance indexes such as a fantastic sensitivity of 521.69 kP and a broad linear sensing detection range of 200 kPa using the electric double layer (EDL) effect of MXene ( )/robust aramid nanofiber (ANF) electrodes, ionic film, and fiber spacer layer. Moreover, they also used the serpentine island bridge structure to increase the stretching of this array and effectively reduce the crosstalk problem of the array.…”
Section: Applicationsmentioning
confidence: 99%
“…( B ) The coordinates of the units in the sensing array attached to the wrist of the volunteer and a schematic diagram of a stretchable inotropic pressure sensor (SIPS). Reprinted with permission from IEEE [ 205 ]. ( C ) Schematic diagram of an intelligent disease diagnosis system for pulsed signals.…”
Section: Figurementioning
confidence: 99%