1990
DOI: 10.1016/0956-716x(90)90082-r
|View full text |Cite
|
Sign up to set email alerts
|

Stress relaxation of continuous film and narrow line metallizations of aluminum on silicon substrates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1991
1991
2017
2017

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…Stress relaxation during an isothermal hold has been studied by Hershkovitz et al (1985), Doerner and Nix (1988), Flinn et al (1987), Korhonen et al (1990), Shute and Cohen (1992), Shen and Suresh (1995), Thouless (1995), Koike et al (1998), and Keller et al (1999). Thouless et al (1993) measured stress relaxation of copper ÿlms on a silicon substrate at temperatures ranging from 74 • C to 187 • C. They found that the qualitative behavior was well-described by power law creep˙ = A n , but argued that a mechanistic understanding of the values of A and n that were required was lacking.…”
Section: Introductionmentioning
confidence: 97%
“…Stress relaxation during an isothermal hold has been studied by Hershkovitz et al (1985), Doerner and Nix (1988), Flinn et al (1987), Korhonen et al (1990), Shute and Cohen (1992), Shen and Suresh (1995), Thouless (1995), Koike et al (1998), and Keller et al (1999). Thouless et al (1993) measured stress relaxation of copper ÿlms on a silicon substrate at temperatures ranging from 74 • C to 187 • C. They found that the qualitative behavior was well-described by power law creep˙ = A n , but argued that a mechanistic understanding of the values of A and n that were required was lacking.…”
Section: Introductionmentioning
confidence: 97%
“…where c(t = 0) is the initial stress at stress relaxation temperature T, & is a characteristic parameter for stress relaxation rate, and r is a stress relaxation time [7][8][9]. relaxation behaviors for different line widths and at different temperatures, it is convenient to compare the characteristic parameter which indicates the rate of stress relaxation.…”
Section: Resultsmentioning
confidence: 99%
“…The X-ray diffraction technique can also be used for the purpose [60,64,[83][84][85][86][87][88][89][90][91]. A common form of the stress evolution during temperature cycles is now illustrated.…”
Section: Basic Elastic-plastic Responsementioning
confidence: 97%