2023
DOI: 10.3389/frsfm.2023.1125163
|View full text |Cite
|
Sign up to set email alerts
|

Stress quantification in a composite matrix via mechanophores

Abstract: Stress concentrations in polymer matrix composites occur due to non-uniform loadings which develop near the interface between the matrix and reinforcement in a stressed composite. Methods to better understand the evolution of this stress concentration are required for the development of advanced composites. Mechanophores, which are stress responsive molecules, can be embedded into the polymer matrix and used to quantify the local stresses in a loaded composite. In this work, single particle model composites we… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 29 publications
(33 reference statements)
0
5
0
Order By: Relevance
“…To quantitatively assess the stresses within the system, we used a previously developed calibration approach. [ 40 ] This calibration method allows quantitative measurements of stresses developed in an MP‐containing sample assuming fixed imaging conditions and mechanophore content between samples. MP activation/stress calibration was achieved by determining a correlation between the experimental fluorescence micrographs at varying loadings and the calculated stress distributions predicted from the FEA model at corresponding strains.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…To quantitatively assess the stresses within the system, we used a previously developed calibration approach. [ 40 ] This calibration method allows quantitative measurements of stresses developed in an MP‐containing sample assuming fixed imaging conditions and mechanophore content between samples. MP activation/stress calibration was achieved by determining a correlation between the experimental fluorescence micrographs at varying loadings and the calculated stress distributions predicted from the FEA model at corresponding strains.…”
Section: Resultsmentioning
confidence: 99%
“…Utilizing a previous calibration method, [21,40] which established a link between the intensity of experimental MP activation and the stress calculated by FEA of the similar material system, it was possible to measure stress based on MP activation. A comparison of the intensities of two systems -a single glass particle-reinforced composite and a single nylon fiber-reinforced composite-each with a matrix composed of 0.6 wt% SPN functionalized PDMS was carried out to employ this calibration.…”
Section: Quantifying I To 𝝈mentioning
confidence: 99%
See 3 more Smart Citations