2023
DOI: 10.1007/s13369-023-07723-x
|View full text |Cite
|
Sign up to set email alerts
|

Strategy of 5G Base Station Energy Storage Participating in the Power System Frequency Regulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 16 publications
0
1
0
Order By: Relevance
“…At present, most of the research on the PSU participating in system frequency regulation uses PSU as an auxiliary means and does not play a role in a large amount of energy storage. The literature [13] proposed a method for pumped storage units to participate in the system automatic power generation control and frequency regulation operation, which realized the step change of output power by changing the operation state of pumped storage units to realize the pumped storage units auxiliary thermal power units to participate in the system frequency control, but did not explain the advantages and economic benefits of pumped storage units auxiliary thermal power units to participate in the system frequency control. The literature [14][15][16] established a simulation model of the combined wind-fire-storage multi-source system in Simulink, and verified that the pumped storage unit-assisted thermal unit, which can smoothly regulate the fluctuation of wind power and stochastic power output, has a better effect on frequency control for the dynamic situation of load change.…”
Section: Introductionmentioning
confidence: 99%
“…At present, most of the research on the PSU participating in system frequency regulation uses PSU as an auxiliary means and does not play a role in a large amount of energy storage. The literature [13] proposed a method for pumped storage units to participate in the system automatic power generation control and frequency regulation operation, which realized the step change of output power by changing the operation state of pumped storage units to realize the pumped storage units auxiliary thermal power units to participate in the system frequency control, but did not explain the advantages and economic benefits of pumped storage units auxiliary thermal power units to participate in the system frequency control. The literature [14][15][16] established a simulation model of the combined wind-fire-storage multi-source system in Simulink, and verified that the pumped storage unit-assisted thermal unit, which can smoothly regulate the fluctuation of wind power and stochastic power output, has a better effect on frequency control for the dynamic situation of load change.…”
Section: Introductionmentioning
confidence: 99%