2021
DOI: 10.4236/ojmi.2021.112005
|View full text |Cite
|
Sign up to set email alerts
|

Strategies to Improve CT Dose Optimization for Hybrid PET/CT Imaging

Abstract: Background: To evaluate whether current dose reduction strategies for the CT component of hybrid Positron Emission Tomography-Computed Tomography (PET/CT) systems could reduce patient dose with maintaining adequate image quality for PET/CT studies. Materials and Methods: Literature survey was initially based on the selection of keywords and years of publication to identify potentially relevant articles, then the further search was conducted on the authors and references from these articles. The abstract of eac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 32 publications
(43 reference statements)
0
5
0
Order By: Relevance
“…Recently, researchers studied the utility of low- and ultra-low-dose CT protocols and demonstrated that significant reduction in radiation dose can be achieved with no detrimental influence on the diagnostic rates of the biopsy operations. Incorporating these novel CT techniques and decreasing the amount of 18F-FDG provided the bare minimum and is, thus, a partial solution to the problem of increased radiation exposure to patients [ 22 ]. In our investigation, the average radiation exposure per procedure for operating personnel was 0.014 mSv, which is far below the permitted annual limits.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, researchers studied the utility of low- and ultra-low-dose CT protocols and demonstrated that significant reduction in radiation dose can be achieved with no detrimental influence on the diagnostic rates of the biopsy operations. Incorporating these novel CT techniques and decreasing the amount of 18F-FDG provided the bare minimum and is, thus, a partial solution to the problem of increased radiation exposure to patients [ 22 ]. In our investigation, the average radiation exposure per procedure for operating personnel was 0.014 mSv, which is far below the permitted annual limits.…”
Section: Discussionmentioning
confidence: 99%
“…PET/CT is an invaluable tool for providing quantitative measures related to diagnosis, therapy response evaluation, and prediction of numerous health conditions. The widespread application of this imaging technique is a product of its high sensitivity, specificity, and diagnostic accuracy related to the molecular processes in vivo 1,2 …”
Section: Introductionmentioning
confidence: 99%
“…In patients with non‐oncological diseases, the total amount of radiation dose, especially for younger patients or even healthy volunteers poses a stumbling block for using PET, limiting its potentially valuable role. Even more so, the radiation dose is of particular concern in scanning children as they are more sensitive to radiation and have a longer post‐irradiation life expectancy 2 . Furthermore, in various conditions, patients may benefit tremendously by receiving multiple CT and PET/CT scans frequently for monitoring treatment, thereby mostly covering the whole‐body 9,10 .…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations