Strategies for quantitation of endogenous adenine nucleotides in human plasma using novel ion-pair hydrophilic interaction chromatography coupled with tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(28 citation statements)
references
References 41 publications
0
27
0
Order By: Relevance
“…The LODs and limits of quantitation (LOQ) of the CE-ESI-MS method for many tested analytes were in the low nanomolar range, similar to, or better than, prior reports. 26,27 This performance has lower LODs compared with other nucleotide characterization approaches such as LC-MS (in μg/ml) and HILIC-MS (in ng/ml) 45,46 and is well suited for small-volume samples such as cells.…”
Section: Resultsmentioning
confidence: 99%
“…The LODs and limits of quantitation (LOQ) of the CE-ESI-MS method for many tested analytes were in the low nanomolar range, similar to, or better than, prior reports. 26,27 This performance has lower LODs compared with other nucleotide characterization approaches such as LC-MS (in μg/ml) and HILIC-MS (in ng/ml) 45,46 and is well suited for small-volume samples such as cells.…”
Section: Resultsmentioning
confidence: 99%
“…The 400 μl upper aqueous layer was centrifugally filtered through a Millipore cutoff filter to remove the protein content. The filtrate was then centrifugally concentrated and re-suspended in Milli-Q water for the metabolomic analysis at APT via hydrophilic interaction liquid chromatography coupled with tandem mass-spectrometry (HILIC-MS/MS) using previously described methods [20, 21]. …”
Section: Methodsmentioning
confidence: 99%
“…More recently developed ion‐pair reversed‐phase LC–MS methods yielded LODs in the range from 1 to 10 nM for AMP, ADP, and ATP using multiple reaction monitoring and an injection volume of 5 µL . HILIC–MS‐based approaches recently developed for nucleotide profiling in various biological samples provided LODs typically in the range from 2 to 100 nM using MS/MS mode and employing an injection volume of 5 µL . In this context, the proposed sheathless CZE–MS method (used in full scan MS mode only) provided concentration LODs for the studied nucleotides that are comparable to or better than LODs obtained by LC–MS‐based approaches employing multiple reaction monitoring.…”
Section: Resultsmentioning
confidence: 99%