2015
DOI: 10.1088/0953-2048/28/6/062002
|View full text |Cite
|
Sign up to set email alerts
|

Strain induced irreversible critical current degradation in highly dense Bi-2212 round wire

Abstract: The strain induced critical current degradation of overpressure processed straight Bi-2212/Ag wires has been studied at 77 K in self-field. For the first time superconducting properties, lattice distortions, composite wire stress and strain have been measured simultaneously in a high energy synchrotron beamline. A permanent Ic degradation of 5% occurs when the wire strain exceeds 0.60%. At a wire strain of about 0.65% a drastic n-value and Ic reduction occur, and the composite stress and the Bi-2212 lattice pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
25
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(29 citation statements)
references
References 33 publications
4
25
0
Order By: Relevance
“…With the UTM integrated in the ID15 beamline of ESRF the lattice parameter changes, I c , stress and strain of the Bi-2223 HT-CA tape were measured as described in [8]. A critical current of I c =193 A is measured before application of an external load, which is in good agreement with the I c =194 A value that is reported in [19].…”
Section: Bi-2223 Lattice Parameter I C and Stress As A Function Osupporting
confidence: 72%
See 3 more Smart Citations
“…With the UTM integrated in the ID15 beamline of ESRF the lattice parameter changes, I c , stress and strain of the Bi-2223 HT-CA tape were measured as described in [8]. A critical current of I c =193 A is measured before application of an external load, which is in good agreement with the I c =194 A value that is reported in [19].…”
Section: Bi-2223 Lattice Parameter I C and Stress As A Function Osupporting
confidence: 72%
“…This test configuration also enables simultaneous X-ray diffraction (XRD) measurements in transmission geometry in a high energy synchrotron beamline for studying the lattice distortions in the composite wire [6,7]. Here we present the results of a simultaneous XRD, I c , stress-strain study of a Bi-2223 tape, and compare the results with those reported previously for a Bi-2212 wire [8].…”
Section: Introductionmentioning
confidence: 79%
See 2 more Smart Citations
“…Cycling within the initial loading range is however quasireversible. More recent data [31], [32] indicate an extended reversible range. It is not clear how much of this behavior is affected by the porosity and connectivity features of early wires.…”
Section: Hts Materials Focusmentioning
confidence: 88%