2017
DOI: 10.1167/iovs.17-22218
|View full text |Cite
|
Sign up to set email alerts
|

Storage of Porcine Cornea in an Innovative Bioreactor

Abstract: By recreating equivalent IOP and medium renewal, the BR obtained unprecedented storage quality of porcine corneas and preserved their main epithelial, limbal, and endothelial characteristics.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
18
0
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
2
1

Relationship

3
7

Authors

Journals

citations
Cited by 24 publications
(21 citation statements)
references
References 37 publications
(46 reference statements)
2
18
0
1
Order By: Relevance
“…Consistent with our prior experience, 24 , 26 28 , 41 , 50 the perfused porcine anterior segments did not experience the amount of corneal edema reported with other culture techniques. 51 With intact TM, NO increased the facility by approximately 45% in group NO compared with the control group, C. After 360° AIT in experiment 2, we found an NO-mediated facility difference of approximately 60% between AIT-NO and AIT-C, in line with the findings reported by McDonnell et al 44 This difference persisted throughout experiments 1 and 2 but declined toward the end of experiment 1, possibly due to a decreasing TM facility response to NO. The TM makes for a significant contribution to outflow resistance, but not in experiment 2 where the facility enhancement is TM independent.…”
Section: Discussionsupporting
confidence: 91%
“…Consistent with our prior experience, 24 , 26 28 , 41 , 50 the perfused porcine anterior segments did not experience the amount of corneal edema reported with other culture techniques. 51 With intact TM, NO increased the facility by approximately 45% in group NO compared with the control group, C. After 360° AIT in experiment 2, we found an NO-mediated facility difference of approximately 60% between AIT-NO and AIT-C, in line with the findings reported by McDonnell et al 44 This difference persisted throughout experiments 1 and 2 but declined toward the end of experiment 1, possibly due to a decreasing TM facility response to NO. The TM makes for a significant contribution to outflow resistance, but not in experiment 2 where the facility enhancement is TM independent.…”
Section: Discussionsupporting
confidence: 91%
“…Consistent with our prior experience, 21,23,24,34,41,42 the perfused porcine anterior segments did not experience the amount of corneal edema reported with other culture techniques. 43 With intact TM, nitric oxide increased the facility by approximately 45% in group NO compared to the control group, C. After 360° AIT in experiment 2, we found a facility difference of approximately 60% between AIT-NO and AIT-C, in line with the findings reported by McDonnell et al 37 This difference persisted throughout experiments 1 and 2 but declined toward the end of experiment 1, possibly due to a decreasing TM facility response to NO. The TM makes for a significant contribution to outflow resistance, but not in experiment 2 where the facility enhancement is TM-independent.…”
Section: Discussionsupporting
confidence: 91%
“…Shortly thereafter, Mueller injected a preservation solution containing DMSO into the anterior chamber of an eyeball, placing the eyeball in a preservation solution containing glycerol. The cornea was removed before surgery for full-thickness transplantation [100,101]. In 1965, Capella [102] used DMSO as an antifreeze to improve a cryopreservation method, ensuring corneal graft activity.…”
Section: Corneal Cryopreservation Technologymentioning
confidence: 99%