2020
DOI: 10.1021/acsapm.0c01120
|View full text |Cite
|
Sign up to set email alerts
|

Stimuli-Responsive Templated Polymer as a Target Receptor for a Conformation-Based Electrochemical Sensing Platform

Abstract: The use of highly cross-linked molecularly imprinted polymers as a synthetic target receptor has the limitations of restricted accessibility to the binding sites, resulting in a slow response time. Moreover, such artificial receptors often require additional transduction mechanisms to translate target binding events into measurable signals. Here, we propose the development of a single-chain stimuli-responsive templated polymer, without using any covalent interchain cross-linkers, as a target recognition elemen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
21
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 17 publications
(22 citation statements)
references
References 69 publications
1
21
0
Order By: Relevance
“…When the temperature is increased, LCST polymer becomes more hydrophobic and the aggregation number of LCST polymer increased. [59][60][61] Therefore, the extent of wrinkles on the PDbS-rGO surface could be controlled by the aggregation number of PDbS on the rGO surface depending on temperature. AuNPs were used to prove the mechanism of wrinkles on PDbS-rGO.…”
Section: Resultsmentioning
confidence: 99%
“…When the temperature is increased, LCST polymer becomes more hydrophobic and the aggregation number of LCST polymer increased. [59][60][61] Therefore, the extent of wrinkles on the PDbS-rGO surface could be controlled by the aggregation number of PDbS on the rGO surface depending on temperature. AuNPs were used to prove the mechanism of wrinkles on PDbS-rGO.…”
Section: Resultsmentioning
confidence: 99%
“…The parameters employed in the equation were: the number of electrons ( n = 1), Faraday constant (F = 96,485 C mol L −1 ), the concentration of [Fe(CN) 6 ] 4− = 5 × 10 −6 mol cm −3 , and the average diffusion coefficient value of the [Fe(CN) 6 ] 4− in 0.1 mol L −1 KCl = 5.38 × 10 −6 cm 2 s −1 [ 41 ]. The one-way ANOVA test was performed ( n = 3) with significance defined as p < 0.05 to check whether the device-to-device surface variation during the optimization of fabrication or analytical parameters—e.g., type of PLE, biEP and sec-IgG concentrations, serum dilution ratio, and time of exposition—was significant, as done in studies found in the literature [ 42 , 43 ]. Then, a two-tailed Students t -test with a confidence level of 95% was performed for pairwise comparisons.…”
Section: Methodsmentioning
confidence: 94%
“…Then, a two-tailed Students t -test with a confidence level of 95% was performed for pairwise comparisons. [ 42 , 43 ].…”
Section: Methodsmentioning
confidence: 99%
“…The intention was to develop an immunosensor utilizing a drop-casting approach with glutaraldehyde (GA) to sensitize the electrode surface. GA has been widely used to modify electrode surfaces due to its introduction of aldehyde functional groups that allow the covalent bonding of compounds containing terminal amino moieties such as EPs [19]. Next, production of the SPE was optimized.…”
Section: Development Of Electrochemical Immunosensormentioning
confidence: 99%