Steroid Hormone Analysis by Tandem Mass Spectrometry

Abstract: BACKGROUND New high-performance liquid chromatography/ tandem mass spectrometry (LC-MS/MS) methods are among the most successful approaches to improve specificity problems inherent in many immunoassays. CONTENT We emphasize problems with immunoassays for the measurement of steroids and review the emerging role of LC-MS/MS in the measurement of clinically relevant steroids. The latest generation of tandem mass spectrometers has superior limits of quantification, permitting omission of previously employed deri… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
151
0
3

Year Published

2009
2009
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 242 publications
(161 citation statements)
references
References 43 publications
7
151
0
3
Order By: Relevance
“…The use of LC-MS/MS as an analytical tool has become popular in a growing number of laboratories seeking to quantify hormone concentrations (Soldin & Soldin, 2009;Field, 2013;Keefe et al, 2014). The technique demonstrates impressive analytical specificity and is argued to be free of many of the limitations of IAs (e.g.…”
Section: Assessing the Validity Of Eias With Liquid Chromatography Tamentioning
confidence: 99%
See 1 more Smart Citation
“…The use of LC-MS/MS as an analytical tool has become popular in a growing number of laboratories seeking to quantify hormone concentrations (Soldin & Soldin, 2009;Field, 2013;Keefe et al, 2014). The technique demonstrates impressive analytical specificity and is argued to be free of many of the limitations of IAs (e.g.…”
Section: Assessing the Validity Of Eias With Liquid Chromatography Tamentioning
confidence: 99%
“…Based on the increasing use of LC-MS/MS for measuring hormones (for reviews see Soldin &Soldin, 2009 andField, 2013), researchers may wish to adopt LC-MS/MS for more accurate testosterone measurement, when feasible. LC-MS/MS is more costly than conducting…”
mentioning
confidence: 99%
“…Novel mass spectrometry techniques hyphened with liquid chromatography has become an important tool that continues to accelerate clinical research and clinical laboratories routines since the past decade [11]. The last generation of tandem mass spectrometers has superior limits of quantification, permitting omission or previously employed derivatization steps [11].…”
Section: Discussionmentioning
confidence: 99%
“…Általános vélekedéssé vált azonban, hogy ezek analitikai teljesítményjellemzői sok tekintetben elfogadhatatlanok. A kialakult álláspontot igazolja, hogy a College of American Pathologists által 2008-ban lebonyolított szteroid külső körvizsgálatban azonos immunoassay-módszerrel kapott E2-eredmények között kilencszeres eltérés volt [62]. Hsing és mtsai radioimmunoassay (RIA) és gázkromatográffal kapcsolt tömeg-spektrométerrel (GC-MS), illetve folyadékkromatográf-fal kapcsolt tandem tömegspektrométerrel (LC-MS/ MS) végzett vizsgálatok során kapott eredményeket hasonlítottak össze, és azt találták, hogy az ösztrogének ÖSSZEFOGLALÓ KÖZLEMÉNY RIA-módszerrel kapott szintjei mintegy 50%-kal voltak magasabbak [63].…”
Section: Az öSztrogénmetabolitok Vizsgálati Lehetőségeiunclassified