2020
DOI: 10.3390/jmse8060397
|View full text |Cite
|
Sign up to set email alerts
|

Stereo Particle Image Velocimetry Measurements of the Wake Fields Behind A Panamax Bulker Ship Model Under the Ballast Condition

Abstract: Particle image velocimetry is applied in this study to measure the wake flow field of a Panamax Bulker ship model under the ballast condition. This investigation revealed that the Froude number is 0.167. The time-averaged velocity, turbulent fluctuations, turbulent kinetic energy (TKE), Reynolds stresses, and vorticity information were measured to perform a comparison with the design condition. The time-averaged velocity contours indicated that the ballast and design conditions have distinct hook-like axial ve… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 18 publications
0
4
0
Order By: Relevance
“…The minimum spacing of the vector grid of one velocity vector in the time-averaged velocity map from 250 images per run was 2.45 × 2.45 mm 2 . In this study, the uncertainty and convergence analysis referred to by Falchi et al [9] and Bendat and Piersol [42,43] was basically the same as that in previous work [39][40][41], and the detailed uncertainty analysis method and convergence analysis process of the present SPIV are not described again. The distribution of the measurement errors was used to determine a 95% confidence interval that contained the true displacement.…”
Section: Analysis Of the Velocity Fieldmentioning
confidence: 97%
See 2 more Smart Citations
“…The minimum spacing of the vector grid of one velocity vector in the time-averaged velocity map from 250 images per run was 2.45 × 2.45 mm 2 . In this study, the uncertainty and convergence analysis referred to by Falchi et al [9] and Bendat and Piersol [42,43] was basically the same as that in previous work [39][40][41], and the detailed uncertainty analysis method and convergence analysis process of the present SPIV are not described again. The distribution of the measurement errors was used to determine a 95% confidence interval that contained the true displacement.…”
Section: Analysis Of the Velocity Fieldmentioning
confidence: 97%
“…The water was seeded with neutrally buoyant white polyamide tracer particles (PSP-50 Dantec Dynamics Inc., Skovlunde, Denmark) with an average diameter of 50 µm using a self-designed and manufactured particle-seeding device with customized rake-shaped pipes. The calibration and seeding processes have been described in detail in previous studies [12,[39][40][41].…”
Section: Test Detailsmentioning
confidence: 99%
See 1 more Smart Citation
“…The size of the interrogation region is 2.45 × 2.45 mm. The 16 × 16-pixel interrogation window was employed to calculate the velocity vectors based on adaptive correlation method [30][31][32]. And the average number of particles in each interrogation region is about 22.…”
Section: Nonstandard Calibration For Piv Systemmentioning