1997
DOI: 10.1366/0003702971940576
|View full text |Cite
|
Sign up to set email alerts
|

Step-Scan FT-IR Photoacoustic Spectroscopy: The Signal Phase

Abstract: The model of Rosencwaig and Gersho for the photoacoustic effect is tested. The use of carbon black samples as a phase reference to estimate the apparatus phase φapp from the experimental signal phase φexp turned out to be ambiguous. A new method is presented to correct the experimental signal phases φexp of polymer films for the apparatus phase φapp. The photoacoustic signal phase of some well-defined poly(ethyleneterephthalate) (PET) films is obtained. As a phase reference, transparent thermally thick polymer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1998
1998
2007
2007

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…As a result of the great experimental PA phase range of the double layer (⌬Ϸ80°), one has to rotate the reference phase coordinates to obtain both the In and Qu interferogram ͑still including app ͒ in the first quadrant of the phase diagram, as discussed earlier. 15 Additionally, we shifted the whole phase spectrum to set transparent ͑in the region between 1550 and 1650 cm Ϫ1 ͒ to 110°, as obtained from the simulations ͑Table IV͒.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…As a result of the great experimental PA phase range of the double layer (⌬Ϸ80°), one has to rotate the reference phase coordinates to obtain both the In and Qu interferogram ͑still including app ͒ in the first quadrant of the phase diagram, as discussed earlier. 15 Additionally, we shifted the whole phase spectrum to set transparent ͑in the region between 1550 and 1650 cm Ϫ1 ͒ to 110°, as obtained from the simulations ͑Table IV͒.…”
Section: Resultsmentioning
confidence: 99%
“…͑For a single-layer system this was done for the CϭO absorption peak of PET. 15 ͒ For ⍜/a g , the full Eq. ͑2͒ was used without simplification or approximation.…”
Section: Experimental Setup and Numerical Simulationmentioning
confidence: 99%
See 1 more Smart Citation
“…Some of them contain general content of the use and application of FT-IR/PAS [22][23][24][25][26][27][28][29][30][31], others are more specific and are devoted to real-time PA parallel detection of products from catalyst libraries [32], step-scan and depth profiling analysis [33][34][35][36][37][38][39][40], the effect of particle size on FT-IR/PAS spectra [41][42][43][44], the temperature effect on PA signal [45], sample emission effects [46], and synchrotron IR/PAS [47]. During a PA measurement the sample is enclosed in a small, tightly closed sample compartment called PA cell [48][49][50][51][52][53][54].…”
Section: Introductionmentioning
confidence: 99%
“…Carbon-black-lled rubbers containing various amounts of carbon black are the most comm on phase references, [5][6][7][8]10 but carbon-black powder, 11,12 and a carbon-black-coated membrane 13 have also been used. Wahls et al 14 avoided possible ambiguities with a strongly absorbing reference by using transparent regions of polymers as references. Others dispensed with a separate reference m aterial by assigning 08 to the phase that maximizes the signal, 9,15 and still others did without any reference at all, using an arbitrary scale and relying on the reproducibility of their instrument and procedure.…”
Section: Introductionmentioning
confidence: 99%