1986
DOI: 10.1016/0167-6105(86)90046-2
|View full text |Cite
|
Sign up to set email alerts
|

Steady wind pressures on solar collectors on flat-roofed buildings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 57 publications
(22 citation statements)
references
References 2 publications
0
15
0
1
Order By: Relevance
“…In this respect, SWHs are rapidly becoming an integral part of worldwide measures to combat the effects of climate change. Previous studies [1,2] found that the wind loads on solar collectors are significantly reduced by the sheltering effect of the first row of collectors and of the building itself. For a residential SWH (an inclined solar collector with a horizontal water storage tank), normal to the direction of smooth uniform wind, the study by Chung et al [3,4] demonstrated that localized wind loads at a tilt angle of 15-30 deg.…”
Section: Introductionmentioning
confidence: 99%
“…In this respect, SWHs are rapidly becoming an integral part of worldwide measures to combat the effects of climate change. Previous studies [1,2] found that the wind loads on solar collectors are significantly reduced by the sheltering effect of the first row of collectors and of the building itself. For a residential SWH (an inclined solar collector with a horizontal water storage tank), normal to the direction of smooth uniform wind, the study by Chung et al [3,4] demonstrated that localized wind loads at a tilt angle of 15-30 deg.…”
Section: Introductionmentioning
confidence: 99%
“…Some authors, e.g., Chevalier and Norton [4], measured the moments as well, but the data is limited: the pitch (overturning) moment has not been reported. Radu et al [5] determined wind force coefficients on solar collector arrays mounted on a typical five-story building. Kopp et al [6] measured the loading on PV arrays in a wind tunnel that simulated the atmospheric boundary layer and the building on which the array was mounted.…”
Section: Introductionmentioning
confidence: 99%
“…Studies have been performed to estimate wind loads on PV panels and solar collectors. Radu et al (1986) studied wind loads on arrays of solar collectors on the flat roof of a five storey building. Dominance of lift on the solar collectors for any wind direction was observed since the flow separated at the leading edge of the roof and did not reattach.…”
Section: Introductionmentioning
confidence: 99%