Sign up to set email alerts
|

Steady state analysis of high penetration PV on utility distribution feeder

Abstract: The current deregulation trend in the electric power industry has led to the utilities trying to adapt Distributed Generation (DG) into their existing infrastructure. In this paper, 12.47 kV distribution feeders of American Electric Power (AEP) are modeled in OpenDSS to investigate the impacts of PV integration. With increasing PV penetration reverse power may flow on the grid which is associated with voltage rise that may lead to violation of integration standards. The impact on voltage profiles and losses de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
17
0
4

Year Published

2016
2016
2021
2021

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 37 publications
(21 citation statements)
references
References 1 publication
(1 reference statement)
0
17
0
4
Order By: Relevance
“…This average for delivery determines the time necessary for extracting the stored energy. If the system load demand requires a high amount of energy from the ESS, then the system configuration is not adequate despite the location of the DG [6].…”
Section: Depth Of Discharge-dodmentioning
confidence: 99%
See 1 more Smart Citation
“…This average for delivery determines the time necessary for extracting the stored energy. If the system load demand requires a high amount of energy from the ESS, then the system configuration is not adequate despite the location of the DG [6].…”
Section: Depth Of Discharge-dodmentioning
confidence: 99%
“…Considering that in the next 20-30 years every type of sustainable energy should be based on rational use from traditional sources and greater use of renewable sources [6], one concludes that the development of techniques for the control of operational levels of distribution systems will be necessary.…”
Section: Introductionmentioning
confidence: 99%
“…Se a relação entre a geração fotovoltaica e a carga instalada for grande, provavelmente a elevação de tensão será um problema, como apresentado em [55], em que a relação de 50% (carga média e produção fotovoltaica alta) ocasionou sobretensões proibitivas, e o regulador automático de tensão não foi eficaz no controle da tensão.…”
Section: Elevação De Tensãounclassified
“…Devido ao auxílio dos geradores no suprimento da demanda de potência ativa, a corrente que flui pelo alimentador, provinda da subestação, diminui, e consequentemente haverá uma redução das perdas totais do sistema. No entanto, dependendo da quantidade de potência fotovoltaica instalada, a influência sob as perdas pode ter um caráter negativo [55]. O excesso de geradores pode causar o fluxo de potência reverso nas linhas de distribuição, acarretando na elevação das perdas técnicas, uma vez que poderá ocorrer um maior fluxo de potência ativa na rede [3].…”
Section: Perdas Técnicas 35unclassified
See 1 more Smart Citation