2007
DOI: 10.1016/j.ijheatmasstransfer.2006.08.008
|View full text |Cite
|
Sign up to set email alerts
|

Steady forced convection heat transfer from a heated circular cylinder to power-law fluids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

21
67
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 145 publications
(90 citation statements)
references
References 49 publications
21
67
0
Order By: Relevance
“…For the zero magnetic field ( ) 0 β = case, good agreement of results can be seen wherein. However, we observe a consistent and slightly higher value for the drag coefficient obtained in the Bharti et al [28] 3.282…”
Section: Code Validationsupporting
confidence: 89%
See 1 more Smart Citation
“…For the zero magnetic field ( ) 0 β = case, good agreement of results can be seen wherein. However, we observe a consistent and slightly higher value for the drag coefficient obtained in the Bharti et al [28] 3.282…”
Section: Code Validationsupporting
confidence: 89%
“…Further the data for mean Nusselt number m N is also compared against other reported data [28] [58]- [72] and it is tabulated in Table 3. It is observed that out of the data shown in table, 71% of researchers have reported the value of mean Nusselt number close to our value of 3.29, whereas others have reported a higher value close to 3.48.…”
Section: Code Validationmentioning
confidence: 99%
“…This is due to the fact that addition of nanoparticles to the base-fluid decreases the nanofluid Prandtl number (as shown in Fig. 2 right) and entirely consistent with the earlier findings in the context of the forced convection of generalized Newtonian fluids from a heated cylinder [29]. Re bf for water-based nanofluids at φ = 2,5 % (left) and φ = 10 % (right).…”
Section: Mean Nusselt Numbersupporting
confidence: 88%
“…In addition to the aforementioned grid-dependency study, the present simulation results have also been compared against the available results of other authors [29,30] for the forced convection in Newtonian fluid from heated circular cylinder. The comparisons between the present numerical results (obtained with mesh MIII ) with the benchmark values (summarised in Table III) are extremely good and entirely consistent with our grid-dependency studies.…”
Section: Grid Refinement Numerical Accuracy and Validationmentioning
confidence: 99%
“…In Figure 8, the local radiative heat flux, convective heat flux, and local temperature on the kiln surface are shown. The convective heat flux distribution is almost the same on the front half of the kiln, as shown in Figures 5 and 8, however, for high Reynolds numbers (as considered in this study), it is higher for the isothermal condition than that for the isoflux condition in the rear half of the cylinder [40]. under an unsteady solution.…”
Section: Supporting Studymentioning
confidence: 53%