“…2) and for the coupling line with the tandem. A 7 Li beam generated locally in the EXCYT target-ion-source assembly as positive ion and transformed in negative ion in the charge Different operating conditions of CEC have been explored, the charge exchange efficiency for the 25 keV lithium beam was of 0.72% as expected from the test at Oak Ridge Laboratory [4].…”
Section: Excyt Commissioning With Stable Beams and First Ribs Productionmentioning
confidence: 99%
See 2 more Smart Citations
“…2) and for the coupling line with the tandem. A 7 Li beam generated locally in the EXCYT target-ion-source assembly as positive ion and transformed in negative ion in the charge Different operating conditions of CEC have been explored, the charge exchange efficiency for the 25 keV lithium beam was of 0.72% as expected from the test at Oak Ridge Laboratory [4].…”
Section: Excyt Commissioning With Stable Beams and First Ribs Productionmentioning
confidence: 99%
“…Moreover, since the CEC showed an increase of efficiency by decreasing the lithium beam energy [4], we decided to lower the TIS extraction voltage. The best operating point was found experimentally at 10 kV permitting to obtain higher CEC efficiency with negligible beam losses over the HV platforms with respect to higher Li beam energy.…”
Section: Excyt Commissioning With Stable Beams and First Ribs Productionmentioning
confidence: 99%
See 1 more Smart Citation
“…The EXCYT (EXotics with Cyclotron and Tandem) facility at INFN-LNS is designed to produce radioactive ion beams [4]. The diagnostic element located near the Target Ion Source will operate at 50 kV with respect to the platform, in a high-activity and high-temperature region.…”
Section: Introductionmentioning
confidence: 99%
“…geoplotlib provides a simple yet powerful API to generate geographical visualizations on OpenStreetMap [12] tiles. We release geoplotlib as open-source software [13], accompanied by a rich set of examples and documentation.…”
Section: Introductionmentioning
confidence: 99%