2013
DOI: 10.1109/tim.2012.2225930
|View full text |Cite
|
Sign up to set email alerts
|

Status of the BIPM Watt Balance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(32 citation statements)
references
References 7 publications
0
32
0
Order By: Relevance
“…A similar watt balance magnet is employed in many NMI watt balances, e.g. the BIPM watt balance [5], METAS-II watt balance [4], NIST-4 watt balance [15], KRISS watt balance [16].…”
Section: Review Of An Ideal Case With 1/r Magnetic Fieldmentioning
confidence: 99%
See 1 more Smart Citation
“…A similar watt balance magnet is employed in many NMI watt balances, e.g. the BIPM watt balance [5], METAS-II watt balance [4], NIST-4 watt balance [15], KRISS watt balance [16].…”
Section: Review Of An Ideal Case With 1/r Magnetic Fieldmentioning
confidence: 99%
“…A handful of national metrology institutes (NMIs) have designed and constructed watt balances [1][2][3][4][5][6][7], a high-precision force comparator leading the effort in redefining the SI unit of mass, the kilogram (kg), in terms of the Planck constant h, expected to culminate in 2018 [8]. A watt balance experiment is comprised of two modes of operation, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…In this experiment, the watt balance was mounted on an optical table without any vibration isolation and was composed of simplified components and measurement facilities. The fully operational apparatus was capable of producing Planck constant values with a type A uncertainty of 10 −6 and a type B uncertainty of the order of 10 −5 [6]. The type A uncertainty was limited mainly by the poor laboratory environment whereas the type B uncertainty was limited mainly by alignment capabilities.…”
Section: Bipm Watt Balancementioning
confidence: 99%
“…The results are deduced from a single measurement with the coil moving upwards. We mention that the new measurements were carried out using a bifilar coil [6] instead of a single working coil. The wire length of each winding of the bifilar coil is thus approximately half of that of the normal working coil.…”
Section: Improvementmentioning
confidence: 99%
“…The BIPM is developing a novel watt balance in order to realize the forthcoming new definition of the kilogram in terms of the Planck constant, h, at the 10 -8 level [1]. A type A uncertainty of about 10 −6 and a type B uncertainty of several parts in 10 −5 was achieved using the first experiment conducted in a non-ideal environment inside a temporary laboratory.…”
Section: Introductionmentioning
confidence: 99%