2012
DOI: 10.1109/tbme.2012.2194783
|View full text |Cite
|
Sign up to set email alerts
|

Statistically Reliable and Fast Direct Estimation of Phase-Amplitude Cross-Frequency Coupling

Abstract: There is growing interest in phase-amplitude cross-frequency coupling (PAC), which is widely observed in human and animal brain recordings. The choice of the estimation method is vital while extracting accurate PAC parameters from data. Two desired properties of PAC estimators are reliability and computational efficiency. This study offers a methodology called normalized direct PAC (ndPAC) for the rapid and statistically reliable estimation of PAC strength. A plain confidence limit formula, depending solely on… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(22 citation statements)
references
References 32 publications
0
22
0
Order By: Relevance
“…As a complementary approach for studying LFP power modulation within the tremor cycle, we computed phase‐amplitude coupling (PAC) between the phase of the tremor envelope and the amplitude of HFOs. PAC at individual tremor frequency was quantified by the normalized direct PAC estimator . Preferred phases can be readily derived from this measure.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…As a complementary approach for studying LFP power modulation within the tremor cycle, we computed phase‐amplitude coupling (PAC) between the phase of the tremor envelope and the amplitude of HFOs. PAC at individual tremor frequency was quantified by the normalized direct PAC estimator . Preferred phases can be readily derived from this measure.…”
Section: Methodsmentioning
confidence: 99%
“…PAC at individual tremor frequency was quantified by the normalized direct PAC estimator. 33 Preferred phases can be readily derived from this measure. For each STN, epoch-specific PAC spectra were combined by computing a weighted average.…”
Section: Phase-amplitude Couplingmentioning
confidence: 99%
See 1 more Smart Citation
“…Although powerful, such surrogate approaches are computationally expensive. A recent approach to determine an analytic procedure assessing the significance of CFC was presented in (Ozkurt, 2012). Second, many existing measures accurately detect only monophasic relationships (i.e., the phase-amplitude probability density has at most one peak (Penny et al, 2008; Özkurt and Schnitzler, 2011)), although entropy-based measures try to overcome this (Canolty et al, 2006b; Tort et al, 2010b).…”
Section: Introductionmentioning
confidence: 99%
“…In order to quantify PAC, a number of methodologies and implementations have been proposed [35][36][37][38][39][40][41][42][43][44] and compared [43,44]. Until now, there is still no gold standard on which method is the best alternative, even though the Kullback-Leibler Distance [44] is probably the most widely adopted due to its noise tolerance and amplitude independence.…”
Section: Introductionmentioning
confidence: 99%