Statistical evaluation of dead time effects and pulse pileup in fast photon counting. Introduction of the sequential model

Abstract: Corrections to photocount distributions due to dead-thne effects are evaluated by the use of a new pulse-plleup model Incorporating a paralyzable portion and nonparalyzable component In sequence. In the simple model, the two dead times are regarded as nonvarying. A more complete model Is presented In the Appendix, which Incorporates dead times that are themselves random variables.1121 amplifier discriminator and a Model 1109 photon counter) and suggest that the counting system can be considered to be composed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

1995
1995
2021
2021

Publication Types

Select...
3
3
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 21 publications
(13 citation statements)
references
References 10 publications
0
12
0
Order By: Relevance
“…Instrument precision was quantified by assessing the dark count noise on each PMT, through sampling zero-air (Lee et al, 2009). Photon counting is a well-established technique, with rates following a Poisson distribution (Ingle and Crouch, 1972;Williamson et al, 1988). Allan variance analysis (Werle, 2011) of 1 hour of 'zero-air' data, gave a 2σ precision (limit of detection) for NO and NO2 of 49 and 78 pptv, at an integration period of 9 Hz.…”
Section: Instrumentationmentioning
confidence: 99%
“…Instrument precision was quantified by assessing the dark count noise on each PMT, through sampling zero-air (Lee et al, 2009). Photon counting is a well-established technique, with rates following a Poisson distribution (Ingle and Crouch, 1972;Williamson et al, 1988). Allan variance analysis (Werle, 2011) of 1 hour of 'zero-air' data, gave a 2σ precision (limit of detection) for NO and NO2 of 49 and 78 pptv, at an integration period of 9 Hz.…”
Section: Instrumentationmentioning
confidence: 99%
“…Equation (14) shows that σ 2 z and σ 2 y are related to each other by the factor G h (0) △t, which can be easily computed. Indeed, since G h (0) = ∆t ∑ h 2 j and, ∆t ∑ h j = 1, we can write (15) or, in terms of the first two moments of h, as…”
Section: Theoretical Backgroundmentioning
confidence: 99%
“…Note that a further increase of the count rate would be troublesome because pile up effects [15] would become dominant and affect both the count rate and the statistics of the pulse stream delivered by the board. An example of this effect is shown below.…”
Section: Simulator Architecturementioning
confidence: 99%
See 1 more Smart Citation
“…Note that the dose response data has been corrected for PMT dead time (Williamson et al 1988). This is typically a minor effect, but it can reduce the PMT counts by as much as 6% at the highest dose studied (500 Gy), depending on the readout protocol.…”
Section: MV Irradiations -Dose Responsementioning
confidence: 99%