Static simulation of voltage instability considering effects of governor characteristics and voltage and frequency dependence of loads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2011
2011
2015
2015

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…The set of measurements used by the MASE are generated from a power flow (PF) analysis of the modified IEEE 118-bus test system. In this case, the PF program permits the modeling of FACTS controllers, ALFC devices, and dependent loads, where only one reference node must be chosen to set the voltage angle profile in the solution [34]. After this study, a total set of 968 measurements is generated to perform the MASE study, where 146 synchronized phasor measurements are provided by 12 PMUs placed at control areas 2, 4, 6, and 7.…”
Section: Study Casementioning
confidence: 99%
See 1 more Smart Citation
“…The set of measurements used by the MASE are generated from a power flow (PF) analysis of the modified IEEE 118-bus test system. In this case, the PF program permits the modeling of FACTS controllers, ALFC devices, and dependent loads, where only one reference node must be chosen to set the voltage angle profile in the solution [34]. After this study, a total set of 968 measurements is generated to perform the MASE study, where 146 synchronized phasor measurements are provided by 12 PMUs placed at control areas 2, 4, 6, and 7.…”
Section: Study Casementioning
confidence: 99%
“…These estimations are compared with those values obtained by the power flow program used to generate the measurements [34] and with the estimations provided by a centralized SE implemented for this purpose based on the theory reported in Section 2; note that the same results were arrived at. Similarly, this validation is also met for the estimated values of the network state variables.…”
Section: Study Casementioning
confidence: 99%
“…Some scholars take the static reactive power-voltage characteristics of generators and (or) loads into consideration [9][10][11] in their studies of steady-state operation analysis. The frequency regulation characteristics of generators are involved in models in Refs [12][13][14][15]. However, it needs to form the Jacobian matrix repeatedly in every iteration of the solution procedure, which will result in a large amount of calculation, and may not meet the requirement of online computation as the power system become larger and more complex.…”
Section: Introductionmentioning
confidence: 99%