2017
DOI: 10.1016/j.rboe.2017.01.008
|View full text |Cite
|
Sign up to set email alerts
|

Static bending test after proximal femoral nail (PFN) removal – in vitro analysis

Abstract: ObjectiveTo evaluate, through biomechanical testing, the resistance to and energy required for the occurrence of proximal femoral fracture in synthetic bone after removal of a proximal femoral nail model (PFN), comparing the results obtained with a reinforcement technique using polymethylmethacrylate (PMMA).MethodsFifteen synthetic bones were used: five units for the control group (CG), five for the test group without reinforcement (TGNR), and five for the test group with reinforcement (TGR). The biomechanical… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
6
0
3

Year Published

2018
2018
2021
2021

Publication Types

Select...
3

Relationship

3
0

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 13 publications
(14 reference statements)
0
6
0
3
Order By: Relevance
“…We compared our results to a similar work in which the authors used the same method and synthetic model but using a proximal femoral nail (PFN) instead of a DHS [9]. Paiva et al described statistically significant results comparing the groups with and without cement filling, a very intriguing result, since the PFN screw used in the study was 10.5 mm in diameter, smaller than the 12.0 mm of the DHS screw used in our research.…”
Section: Discussionmentioning
confidence: 66%
See 2 more Smart Citations
“…We compared our results to a similar work in which the authors used the same method and synthetic model but using a proximal femoral nail (PFN) instead of a DHS [9]. Paiva et al described statistically significant results comparing the groups with and without cement filling, a very intriguing result, since the PFN screw used in the study was 10.5 mm in diameter, smaller than the 12.0 mm of the DHS screw used in our research.…”
Section: Discussionmentioning
confidence: 66%
“…The proximity of the cement filling to the uppermost part of the femoral neck in the PFN group, as compared to our study with DHS, was on the fall over the trochanter. It is, therefore, possible that the closer to this region, the greater the resistance implemented by the reinforcement, leading us to believe that one of the main factors of the increased strength with PMMA in the proximal femoral extremity is not only about the volume of PMMA used but also its positioning, a fact already mentioned in other publications [9-12].…”
Section: Discussionmentioning
confidence: 91%
See 1 more Smart Citation
“…In a similar work, in which the author uses the same methodology and the same synthetic model, but with HFP, the results were statistically significant 15 ; our study had a very intriguing result, because the HFP was filled in only one specific place: a 10.5-mm sliding screw tunnel, with a PMMA volume of 9 mL. We noticed that the main difference was the tension provided by the PMMA reinforcement, since two specimens from our study had diaphyseal fractures.…”
Section: Discussionmentioning
confidence: 67%
“…There is a concern about the volume used due to the local thermal reaction. 9 15 The volume used in our study is similar to that used in other works, showing little local thermal variation. 10 14…”
Section: Discussionmentioning
confidence: 87%