2007
DOI: 10.1080/08927020701275050
|View full text |Cite
|
Sign up to set email alerts
|

State point dependence of systematically coarse–grained potentials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
47
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
7
2
1

Relationship

1
9

Authors

Journals

citations
Cited by 60 publications
(49 citation statements)
references
References 31 publications
2
47
0
Order By: Relevance
“…4,10,13 However, an important drawback of the method is the strong state-point dependence and limited transferability of the potentials. 4,13−16 Nevertheless, studies showed that the temperature transferability can be improved through a careful choice of mapping point(s) 17 and/or inclusion of sufficient chemical detail.…”
Section: Introductionmentioning
confidence: 99%
“…4,10,13 However, an important drawback of the method is the strong state-point dependence and limited transferability of the potentials. 4,13−16 Nevertheless, studies showed that the temperature transferability can be improved through a careful choice of mapping point(s) 17 and/or inclusion of sufficient chemical detail.…”
Section: Introductionmentioning
confidence: 99%
“…This degeneracy (in a mathematical sense) is perhaps already foreshadowed by the variety of CG methods that have been successfully developed: empirical Leonard Jones (LJ) potentials, 11,18,47 iterative Boltzmann inverseion (IBI), 10,16,17 FM, 5,6 etc.. But even within the context of a single method, statistical under-sampling, numerical error, and uncertainty in target data suggest that it is difficult, if not impossible to identify a unique, optimal force for a given coarse-graining procedure.…”
Section: Discussionmentioning
confidence: 99%
“…Recent research has also demonstrated that the potentials calculated to ensure structural consistency between a particular atomically detailed model and a CG model of the same system can demonstrate significant and nontrivial dependence upon the particular thermodynamic state point used to parametrize the potentials. 44,45,[50][51][52][53][54][55][56] This research indicates that achieving complete transferability 43 of CG model parameters across different conditions is intrinsically in conflict with the CG modeling approach because constructing a reduced representation of an atomically detailed system inevitably involves including some amounts of information regarding its thermodynamic state into the CG representation. Partial transferability of a given set of model parameters can possibly be achieved, but at the cost of sacrificing quantitative consistency.…”
Section: Molecular Dynamics ͑Md͒mentioning
confidence: 99%