2009
DOI: 10.4248/ijos09031
|View full text |Cite
|
Sign up to set email alerts
|

State of the Art of Micro‐CT Applications in Dental Research

Abstract: This review highlights the recent advances in X-ray microcomputed tomography (Micro-CT) applied in dental research. It summarizes Micro-CT applications in measurement of enamel thickness, root canal morphology, evaluation of root canal preparation, craniofacial skeletal structure, micro finite element modeling, dental tissue engineering, mineral density of dental hard tissues and about dental implants. Details of studies in each of these areas are highlighted along with the advantages of Micro-CT, and finally … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
244
0
32

Year Published

2012
2012
2021
2021

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 310 publications
(276 citation statements)
references
References 79 publications
0
244
0
32
Order By: Relevance
“…However, these methods require time and are destructive. In contrast, μCT measures the mineral density of hard tissues such as bones and teeth, has a resolution of 5-30 µm, and is more accurate than other methods (12,14). Because the thickness of the sample used for μCT depends on the size of the X-ray beam, slices of the sample examined can be thinner and more regular than samples prepared by physical cutting (10).…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…However, these methods require time and are destructive. In contrast, μCT measures the mineral density of hard tissues such as bones and teeth, has a resolution of 5-30 µm, and is more accurate than other methods (12,14). Because the thickness of the sample used for μCT depends on the size of the X-ray beam, slices of the sample examined can be thinner and more regular than samples prepared by physical cutting (10).…”
Section: Discussionmentioning
confidence: 99%
“…To our knowledge, this is the first report to use μCT to evaluate progression of artificially induced initial caries lesions. There are several methods of measuring mineral concentrations and densities of hard dental tissues, including chemical analyses of microsamples, contact microradiography, and transversal microradiography (12). However, these methods require time and are destructive.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…20-24 A micro-CT system using microfocal spot X-ray sources and high-resolution detectors allows projections to be rotated through multiple viewing directions to produce 3D reconstructed images of samples. 23 With the micro-CT, we obtained 3D reconstructed images of each bracket and evaluated the 3D bracket base surface areas.…”
Section: Discussionmentioning
confidence: 99%
“…Bu yüzden bu kanalların anatomik varyasyonu ve morfolojik yapısının aydınlığa kavuşması gereklidir. 17 C-şekilli kanalları araş-tırmak için mikrotomografi sistemlerini kullanan çeşitli çalışmalar mevcuttur.…”
Section: Bjorndal Ve Arkunclassified