1974
DOI: 10.1088/0022-3700/7/10/012
|View full text |Cite
|
Sign up to set email alerts
|

Stark shifts of singly ionized argon lines

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
18
0

Year Published

1978
1978
2010
2010

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 23 publications
(20 citation statements)
references
References 12 publications
2
18
0
Order By: Relevance
“…One can see that with the exception of the experiment [5], the d~/d~h ratio for the MSE theory varies between 0.72 and 1.53, i.e. Moreover, for the experiment [5] On the basis of the results presented in [1] and in present paper, the MSE approach might be treated in the case of line shifts also as an useful method for simple and fast estimation of Stark broadening parameters with good average accuracy. Moreover, for the experiment [5] On the basis of the results presented in [1] and in present paper, the MSE approach might be treated in the case of line shifts also as an useful method for simple and fast estimation of Stark broadening parameters with good average accuracy.…”
Section: Resultsmentioning
confidence: 55%
See 2 more Smart Citations
“…One can see that with the exception of the experiment [5], the d~/d~h ratio for the MSE theory varies between 0.72 and 1.53, i.e. Moreover, for the experiment [5] On the basis of the results presented in [1] and in present paper, the MSE approach might be treated in the case of line shifts also as an useful method for simple and fast estimation of Stark broadening parameters with good average accuracy. Moreover, for the experiment [5] On the basis of the results presented in [1] and in present paper, the MSE approach might be treated in the case of line shifts also as an useful method for simple and fast estimation of Stark broadening parameters with good average accuracy.…”
Section: Resultsmentioning
confidence: 55%
“…Cases where experimental and theoretical shifts have the opposite signs are denoted by asterisks [2,3] for all experiments considered, except [4] with somewhat higher accuracy, and because of the fact that all measurements are performed in temperature Table 3. One can see that with the exception of the experiment [5], the d~/d~h ratio for the MSE theory varies between 0.72 and 1.53, i.e. it is approximately within _+ 50% limit.…”
Section: Resultsmentioning
confidence: 85%
See 1 more Smart Citation
“…2) are taken from Popenoe & Shumaker (1965), Jalufka et al (1966), Roberts (1966), Chapelle et al (1968ab), Roberts (1968), Konjević et al (1970), Klein (1973), Labat et al (1974), Behringer & Thoma (1978), Vaessen et al (1985), Nick & Helbig (1986), Pittman & Konjević (1986), Vitel & Skowronek (1987), Abbas et al (1988), Djeniže et al (1989), Dzierzega & Musiol (1994), Pellerin et al (1997), Aparicio et al (1998) and Iglesias et al (2006).…”
mentioning
confidence: 99%
“…A number of experimental studies have been devoted to Ar II spectral line Stark parameter measurement (Jalufka, Oertel & Ofelt 1966;Roberts 1966Roberts , 1968Blandin et al 1968;Chapelle et al 1968 ⋆ E-mail: djurovic@uns.ac.rs (SD); apa@opt.uva.es (JAA) a,b; Konjević et al 1970;Morris & Morris 1970;Labat et al 1974;Behinger & Thoma 1978;Nick & Helbig 1986;Pitman & Konjević 1986;Djeniže et al 1989;Dzierzega & Musiol 1994;Aparicio et al 1998a;Iglesias et al 2006). However, there are still a lot of data missing, particularly in the UV region.…”
Section: Introductionmentioning
confidence: 99%