2019
DOI: 10.1167/tvst.8.6.41
|View full text |Cite
|
Sign up to set email alerts
|

Standardizing the Assessment of Macular Pigment Using a Dual-Wavelength Autofluorescence Technique

Abstract: Purpose: It is essential to have an appropriate measure to assess macular pigment (MP) that can provide an accurate, valid, and reliable representation of the MP within the macula. The aim of this study was to describe and introduce MP optical volume (MPOV) as an optimal value for reporting MP. Methods: Three hundred ninety-three subjects were analyzed using the Heidelberg Spectralis with the investigational MP optical density (MPOD) module to measure MPOV and MPOD at four foveal eccentricities (0.238, 0.518, … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
34
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 32 publications
(38 citation statements)
references
References 57 publications
(75 reference statements)
1
34
0
Order By: Relevance
“…MPOD is dimensionless. Therefore, MP volume is also unitless [37]. Like in the other studies, MP volume after the intervention was also higher than before (MP volume change shows +2558).…”
Section: Macular Pigment (Mp)supporting
confidence: 61%
“…MPOD is dimensionless. Therefore, MP volume is also unitless [37]. Like in the other studies, MP volume after the intervention was also higher than before (MP volume change shows +2558).…”
Section: Macular Pigment (Mp)supporting
confidence: 61%
“…Heterochromatic flicker photometry due to its small footprint is perhaps most common clinical device utilized to measure MPOD [4,8,10,15,16,26,41,44,45,48,66,67,72,73]. However, objective techniques such as dual-wavelength autofluorescence [74] or macular pigment reflectometry [21,75,76] could decrease variability in results, given that the participants in this study were clinical patients and not trained participants in a psychophysical study. A learning curve may account for the increase in CSF testing overtime in healthy controls.…”
Section: Discussionmentioning
confidence: 99%
“…Letters are shown for representative values of these functions in older adults with healthy maculas. 34 eccentric than other studies 36 and has been recommended, 35 because it avoids high variance due to non-autofluorescent vasculature at greater eccentricities. We measured mean MPOD for the RMDA test spot (radius = 1°, located 5°, or 1.44 mm, directly superior to the fovea).…”
Section: Metrics For Mpod Mpov Rod:cone Ratio and Minimum Retinal mentioning
confidence: 99%
“…MPOD integrated over the central area, referred to as macular pigment optical volume (MPOV), is proposed as a comprehensive metric. 35,36 Relative to HFP, dual-wavelength autofluorescence MPOD imaging is quicker and more objective, repeatable, and unbiased (i.e., all pixels are included). Its interpretation can benefit from new data on the cellular and subcellular basis of RPE autofluorescence imaging.…”
mentioning
confidence: 99%