2016
DOI: 10.2967/jnumed.115.171595
|View full text |Cite
|
Sign up to set email alerts
|

Standardized Expression of 18F-NAV4694 and 11C-PiB β-Amyloid PET Results with the Centiloid Scale

Abstract: A common quantitative output value for PET measures of β-amyloid (Aβ) binding across tracers and methods would allow better comparison of data across sites and application of universal diagnostic and prognostic values. A method has recently been developed that generates a unit of measurement called the centiloid. We applied this method to 2-[2-18 F-fluoro-6-(methylamino)-3-pyridinyl]-1-benzofuran-5-ol ( 18 F-NAV4694) and 11 C-Pittsburgh compound B ( 11 C-PiB) Aβ images to derive the scaling factor required to … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
73
1

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 92 publications
(79 citation statements)
references
References 26 publications
0
73
1
Order By: Relevance
“…An intertracer correlation of R 2 = 0.99 was observed between PiB and [ 18 F]‐NAV4694, and R 2 = 0.96 was observed between PiB and [ 18 F]‐florbetaben. The variance of amyloid burden measurements in young controls was SD = 3.7 for [ 18 F]‐NAV4694 and SD = 6.81 for [ 18 F]‐florbetaben [14,15]. Recently, Navitsky et al [16] reported an SD = 12.07 for florbetapir, and here, we observed an SD = 14.2 for the raw florbetapir SUVr‐derived Centiloid measurements; however, when the RSF PVC technique was used in the quantification procedure, the variance was substantially reduced (SD = 5.4).…”
Section: Discussioncontrasting
confidence: 47%
See 3 more Smart Citations
“…An intertracer correlation of R 2 = 0.99 was observed between PiB and [ 18 F]‐NAV4694, and R 2 = 0.96 was observed between PiB and [ 18 F]‐florbetaben. The variance of amyloid burden measurements in young controls was SD = 3.7 for [ 18 F]‐NAV4694 and SD = 6.81 for [ 18 F]‐florbetaben [14,15]. Recently, Navitsky et al [16] reported an SD = 12.07 for florbetapir, and here, we observed an SD = 14.2 for the raw florbetapir SUVr‐derived Centiloid measurements; however, when the RSF PVC technique was used in the quantification procedure, the variance was substantially reduced (SD = 5.4).…”
Section: Discussioncontrasting
confidence: 47%
“…These results are in agreement with ours. The Centiloid conversion and comparison to PiB has been reported for two other 18 F‐tracers, that is, [ 18 F]‐NAV4694 [14] and [ 18 F]‐florbetaben [15]. An intertracer correlation of R 2 = 0.99 was observed between PiB and [ 18 F]‐NAV4694, and R 2 = 0.96 was observed between PiB and [ 18 F]‐florbetaben.…”
Section: Discussionmentioning
confidence: 59%
See 2 more Smart Citations
“…describe application of the centiloid methodology for scaling and analysis of studies performed with 18 F-NAV4694 for characterizing cerebral amyloid deposition in clinical research (1). This is one of several evolving approaches to analysis of amyloidtargeting radiotracers that have emerged recently.…”
mentioning
confidence: 99%