2023
DOI: 10.1016/j.jim.2023.113568
|View full text |Cite
|
Sign up to set email alerts
|

Standardization, validation, and comparative evaluation of a faster and high-performance test for quantification of yellow fever neutralizing antibodies

Marisol Simões,
Stephanie Almeida da Silva,
Kelly Araújo Lúcio
et al.
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…In this context, the quantification of YF-specific neutralizing antibodies has been considered the gold standard. In the present study, the micro Focus Reduction Neutralization—Horseradish Peroxidase was used to quantify the YF-specific neutralizing antibodies titers and seropositivity rates, according to the standard protocol of μFRN-HRP described by Simões 12 . The results are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In this context, the quantification of YF-specific neutralizing antibodies has been considered the gold standard. In the present study, the micro Focus Reduction Neutralization—Horseradish Peroxidase was used to quantify the YF-specific neutralizing antibodies titers and seropositivity rates, according to the standard protocol of μFRN-HRP described by Simões 12 . The results are shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…Plasma samples stored at − 80 °C were thawed at 37 °C and pre-treated with ecteola-cellulose for heparin removal as previously described by Campi-Azevedo et al 30 , prior use for the YF-specific micro Focus Reduction Neutralization—Horseradish Peroxidase (μFRN-HRP). The μFRN-HRP test was carried out at Laboratório de Análise Imunomecular, Bio-Manguinhos (LANIM, FIOCRUZ-RJ, Brazil) to quantify the titers of YF-specific neutralizing antibodies and define the seropositivity rates according to Simões 12 , as follows: briefly, in 96-well plates, a mixture of ECT-treated plasma samples (1:6 to 1:1458) plus 17D-213/77 vaccine virus (70 PFU/well) was pre-incubated (2 h; 37 °C; 5% CO 2 ) and transferred to pre-formed Vero ATCC cell monolayer. Carboxymethylcellulose semisolid medium (2%) were added to each well and monolayers incubated for 48 h at 37 °C, 5% CO 2 .…”
Section: Methodsmentioning
confidence: 99%