2006
DOI: 10.1016/j.apradiso.2006.01.012
|View full text |Cite
|
Sign up to set email alerts
|

Standardization of NIRR-1 irradiation and counting facilities for instrumental neutron activation analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
29
0

Year Published

2009
2009
2020
2020

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(30 citation statements)
references
References 7 publications
1
29
0
Order By: Relevance
“…For elements leading to short-lived activation products the samples are each packed and sealed in 7 cm 3 rabbit capsules and sent for irradiation in turn in an outer irradiation channel B 4 where the neutron spectrum is "soft", the choice of the outer irradiation channel is to eliminate corrections, notably Mg in the presence of P. This is due to the proximity of the inner channels of MNSRs to the core leading to relative higher ratio of fast-to-thermal neutron 9 .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For elements leading to short-lived activation products the samples are each packed and sealed in 7 cm 3 rabbit capsules and sent for irradiation in turn in an outer irradiation channel B 4 where the neutron spectrum is "soft", the choice of the outer irradiation channel is to eliminate corrections, notably Mg in the presence of P. This is due to the proximity of the inner channels of MNSRs to the core leading to relative higher ratio of fast-to-thermal neutron 9 .…”
Section: Methodsmentioning
confidence: 99%
“…Under these conditions the reactor can operate with the same fuel loading for over ten (10) years with a burn up of <1%. Neutron flux parameter of MNSRs are known to be stable, thus permitting the use of semi absolute Neutron Activation Analysis (NAA) [5][6][7][8][9] . NAA in its instrumental form, has some unique features which makes it attractive to use for routing analysis.…”
mentioning
confidence: 99%
“…Samples were counted using the plexi-glass holder "H1". The choice of cooling time and sample-detector geometry was such that detector's dead time is controlled to be less than10% (Jonah et al, 2006).…”
Section: Special Conference Edition November 2017mentioning
confidence: 99%
“…Neutron Activation Analysis in its instrumental form (INAA), especially with research reactors, has some unique features, which makes it attractive to use for routine analysis. These are multielement capability, rapidity, reproducibility of results, complementary to other methods, freedom from analytical blank and independence of chemical state of elements (Jonah et al, 2006). These techniques can be used in qualitative as well as in quantitative analysis.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation