Medical Infrared Imaging 2007
DOI: 10.1201/9781420008340.ch22
|View full text |Cite
|
Sign up to set email alerts
|

Standard Procedures for Infrared Imaging in Medicine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
31
0
2

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(36 citation statements)
references
References 14 publications
0
31
0
2
Order By: Relevance
“…Where appropriate, any measurement site with exposed hair was shaved at least 36 h before testing (Togawa and Saito, 1994) to prevent inflammation or damage to the skin surface artificially raising skin temperature and influencing infrared measurements (Merla et al, 2010). In preparation for testing, participants did not engage in exercise, ingest caffeine or alcohol 24 h prior to (Ammer and Ring, 2006), have a hot shower within two hours of arriving to the laboratory and kept the measurement sites clean of ointments and cosmetics (Selfe et al, 2006).…”
Section: Pre-experimental Protocolmentioning
confidence: 99%
See 1 more Smart Citation
“…Where appropriate, any measurement site with exposed hair was shaved at least 36 h before testing (Togawa and Saito, 1994) to prevent inflammation or damage to the skin surface artificially raising skin temperature and influencing infrared measurements (Merla et al, 2010). In preparation for testing, participants did not engage in exercise, ingest caffeine or alcohol 24 h prior to (Ammer and Ring, 2006), have a hot shower within two hours of arriving to the laboratory and kept the measurement sites clean of ointments and cosmetics (Selfe et al, 2006).…”
Section: Pre-experimental Protocolmentioning
confidence: 99%
“…Data collection consisted of repeated skin temperature measurements taken using a calibrated, uncooled digital infrared camera A305sc (FLIR Systems, Wilsonville, Oregon, USA) with an image resolution of 320 Â 240 pixels and a minimal detectable temperature difference of o 0.05°C at 30°C. The infrared camera was positioned on a level tripod perpendicular to the seated, resting participant (90°) at a distance of 0.8-1.1 m depending on the height and size of the participant (Ammer and Ring, 2006). The camera was assembled and allowed to stabilise for at least 60 min prior to subject arrival (Grgić and Pušnik, 2011).…”
Section: Experimental Protocolmentioning
confidence: 99%
“…The room has an ambient temperature of 20 • C and a relative humidity of 50%. Avoidance of air currents on hand subjects and shunning of direct sunlight on the lens are necessary [15]. Additionally, the distance between the infrared camera and the subject's hand is considered.…”
Section: Protocol For Acquisition Of Infrared Imagesmentioning
confidence: 99%
“…Avoidance of air currents on hands subjects and shunning of direct sunlight on lens are necessary [11]. Additionally, the distance between the infrared camera and the subject's hand is considered.…”
Section: B Protocol For Acquisition Of Infrared Imagesmentioning
confidence: 99%
“…The proper position of the subject is important, to ensure that the collection of infrared images remain standardized and avoid uncertainties in the measurements [11].…”
Section: B Protocol For Acquisition Of Infrared Imagesmentioning
confidence: 99%