1971
DOI: 10.1021/je60048a030
|View full text |Cite
|
Sign up to set email alerts
|

Standard potentials of the calcium amalgam electrode at various temperatures, with related thermodynamic functions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
43
0

Year Published

1993
1993
2001
2001

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 68 publications
(43 citation statements)
references
References 6 publications
0
43
0
Order By: Relevance
“…(11) The cell design, and the electrolytic method of deposition of these amalgam electrodes by K deposition on a mercury cathode from aqueous 0.5 mol · kg −1 KOH solution, were described earlier. (12) The verification of the K mole fraction x in the amalgam electrodes used was carried out potentiometrically, by measuring the e.m.f. E I of cell (I) at T = 298.15 K in pure aqueous medium at various molalities m of KCl.…”
Section: Methodsmentioning
confidence: 99%
“…(11) The cell design, and the electrolytic method of deposition of these amalgam electrodes by K deposition on a mercury cathode from aqueous 0.5 mol · kg −1 KOH solution, were described earlier. (12) The verification of the K mole fraction x in the amalgam electrodes used was carried out potentiometrically, by measuring the e.m.f. E I of cell (I) at T = 298.15 K in pure aqueous medium at various molalities m of KCl.…”
Section: Methodsmentioning
confidence: 99%
“…(3) The cell design, the electrolytic method of preparation of these amalgam electrodes (by Na deposition on Hg cathode from aqueous 1 mol·kg − 1 NaOH solution), and the method of control of the mole fraction x of Na in amalgams were described earlier. (5) For all the flowing alkali-metal as well as alkaline-earth dilute-amalgam electrodes, (3) an important factor for accuracy and repeatability of results proved to be the homogenization of amalgams by storage overnight at T = 323 K with efficient stirring and under ultrapure N 2 flow before transfer to the two-capillary-tube amalgam dropper for the e.m.f. measurements.…”
Section: Methodsmentioning
confidence: 99%
“…(6) The thermostatic apparatus was described in an earlier paper. (5) The e.m.f.s. were measured by a Type 619 Keithley digital electrometer at NaCl molalities approximately up to the solubility limit in each solvent mixture considered.…”
Section: Methodsmentioning
confidence: 99%
“…The thermostat was described in a previous paper. (23) In order to reach temperatures <273.15 K, a Type EN 850 Neslab flowthrough cooler was used.…”
Section: Methodsmentioning