2003
DOI: 10.1016/s0021-9614(03)00109-5
|View full text |Cite
|
Sign up to set email alerts
|

Standard molar enthalpies of formation, vapour pressures, and enthalpies of sublimation of 2-chloro-4-nitroaniline and 2-chloro-5-nitroaniline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
49
1
1

Year Published

2004
2004
2010
2010

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 59 publications
(54 citation statements)
references
References 28 publications
3
49
1
1
Order By: Relevance
“…A detailed description of the apparatus and the general operating technique may be found in the literature [14,19,20].…”
Section: Combustion Calorimetry Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…A detailed description of the apparatus and the general operating technique may be found in the literature [14,19,20].…”
Section: Combustion Calorimetry Measurementsmentioning
confidence: 99%
“…Recently, two isomers of chloronitroaniline, 2-chloro-4-nitroaniline and 2-chloro-5-nitroaniline, were the object of a detailed experimental and computational study [14]. In this paper we report the experimental thermochemical study of 4-chloro-3-nitroaniline and 5-chloro-2-nitroaniline, and the computational thermochemistry study of all the isomers of chloronitroaniline.…”
Section: Introductionmentioning
confidence: 99%
“…Both the apparatus and the operating technique have been described [22][23][24][25][26][27] so only a brief description will be given here. The bomb, with an internal volume of 0.258 dm 3 , is of stainless steel lined with platinum, and the internal fittings are machined from platinum.…”
Section: Combustion Calorimetrymentioning
confidence: 99%
“…Both the apparatus and the operating technique have been described [39][40][41][42][43][44] so only a brief description will be given here. The twin valve bomb, with an internal volume of 0.258 dm 3 and wall thickness of 1 cm, is made of stainless steel, internally lined with platinum, with all the internal fittings entirely machined from platinum.…”
Section: Combustion Calorimetrymentioning
confidence: 99%
“…Hence, the accuracy of the calorimeter has been checked in our laboratory by measuring the energy of combustion of 4-chlorobenzoic acid, in the pellet form, in oxygen at p = 3.04 MPa, in the presence of an aqueous solution of As 2 O 3 in the bomb. The results obtained for the enthalpy of combustion of 4-chlorobenzoic acid, D c H m ¼ Àð3064:5 AE 1:2Þ kJ Á mol À1 [41] and D c H m ¼ Àð3063:92 AE 0:91Þ kJ Á mol À1 [44], are in very good agreement with the recommended value, D c H m ¼ Àð3063:48 AE 0:23Þ kJ Á mol À1 [36]. Values of D c H m refer to the reaction with HCl AE 600H 2 O(l) as the chlorine containing product in the final state.…”
Section: Combustion Calorimetrymentioning
confidence: 99%