2018 IEEE Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) 2018
DOI: 10.1109/ceidp.2018.8544887
|View full text |Cite
|
Sign up to set email alerts
|

Standard Evolution for the Determination of the Power Frequency Breakdown Voltages in Insulating Liquids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
0
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(1 citation statement)
references
References 11 publications
0
0
0
Order By: Relevance
“…This test was performed according to the IEC 60156 standard that uses two partial spherical electrodes with a gap of 2.5 and 1.0 mm. The applied voltage was increased with a fixed rate of 2 kV•s -1 ± 0.2 kV•s -1 until breakdown occurs [14]. That is when the output current has been 4 mA or more for at least 5 ms.…”
Section: Methodsmentioning
confidence: 99%
“…This test was performed according to the IEC 60156 standard that uses two partial spherical electrodes with a gap of 2.5 and 1.0 mm. The applied voltage was increased with a fixed rate of 2 kV•s -1 ± 0.2 kV•s -1 until breakdown occurs [14]. That is when the output current has been 4 mA or more for at least 5 ms.…”
Section: Methodsmentioning
confidence: 99%