1977
DOI: 10.1017/s0022172400053031
|View full text |Cite
|
Sign up to set email alerts
|

Standard aeration for gas-sterilized plastics

Abstract: SUMMARYIn an effort to provide guidelines for standardizing aeration times for plastics sterilized with ethylene oxide, an Aeration Index has been developed. Based on the rate of diffusion of ethylene oxide in selected polymers, the Index provides an indication of the aeration time at ambient temperature (23°C) for the ethylene oxide concentration in freshly sterilized plastics to drop to 50 parts/106.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
3
0

Year Published

1986
1986
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 16 publications
(12 reference statements)
1
3
0
Order By: Relevance
“…Approximate first-order rates of EO release from sterilized EO absorbent medical product materials are consistent with the corresponding approximate 2 h typical half-time of EO release (approximate range: 1–6 h) [21,22,24,25]. Similar rates of first-order EO loss from product sterilization of packaging materials (EO permeable plastic enclosures, cardboard boxes and separators, spice bags, etc.)…”
Section: Methodssupporting
confidence: 69%
See 1 more Smart Citation
“…Approximate first-order rates of EO release from sterilized EO absorbent medical product materials are consistent with the corresponding approximate 2 h typical half-time of EO release (approximate range: 1–6 h) [21,22,24,25]. Similar rates of first-order EO loss from product sterilization of packaging materials (EO permeable plastic enclosures, cardboard boxes and separators, spice bags, etc.)…”
Section: Methodssupporting
confidence: 69%
“…d Extrapolated from Late/Medical/health scenario assumptions (see Methods). e Estimated from Bruch [21,22]; Stetson et al [24]; and White [25].…”
Section: Figurementioning
confidence: 99%
“…were sterilized using gamma irradiation. Other sterilization methods were tested and abandoned because ethanol and ethylene oxide readily partition into plastic components(20), and autoclaving is not suitable for the assemblies containing materials with drastically different coefficients of thermal expansion. The 2 partially assembled reactor portions (illustrated in Supplemental Figure S1) allowed for ease in loading the 3D matrix and cell components and the subsequent easy alignment and combination of the two portions into a complete system.…”
Section: Methodsmentioning
confidence: 99%
“…Plot displays time required for residual ethylene oxide to aerate passively below 50 ppm from various medical plastics (LDPE = Low density polyethylene, PP = Polypropylene, PTFE = Polytetrafluoroethylene, PET = Polyethylene terephthalate). Reproduced with permission from ref . Copyright 1977 Cambridge University Press.…”
Section: Sterilization Techniquesmentioning