Stand-Alone Wearable Power Assist Suit –Development and Availability–

Abstract: The stand-alone wearable power assist suit we developed gives caregivers the extra strength they need to lift patients while avoiding back injuries. To put this suit to practical use, we improved sensing system and the mechanisms. To stabilize muscle tenseness sensing more, we developed an all-in-one sensor that built the sensor into a mesh belt and improved sensing characteristics. We expanded the movable range and function of the suit. We increased actuator output torque by increasing the number of cuffs ins… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
45
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 126 publications
(47 citation statements)
references
References 7 publications
0
45
0
Order By: Relevance
“…The tested sensor consists of the ultrasonic sensor mentioned above, an acrylic cover with two tube connecters and a thick flexible tube with an inner/outer diameter of 8/12 mm connected to two thin flexible tubes with an inner/outer diameter of 2.5/4 mm. As a sliding stage, the ring-shaped neodymium magnet with an inner/outer diameter of 13/25 mm, thickness of 5 mm and an acrylic cylindrical reflector with an outer diameter of 7.5 mm and length of 9 mm that a steel ball with an 02002-p. 3 outer diameter of 5 mm were used. Figure 6 shows the construction and operating principle of the measuring system using the tested sensor.…”
Section: Flexible Displacement Sensor Using Flexible Tubementioning
confidence: 99%
See 1 more Smart Citation
“…The tested sensor consists of the ultrasonic sensor mentioned above, an acrylic cover with two tube connecters and a thick flexible tube with an inner/outer diameter of 8/12 mm connected to two thin flexible tubes with an inner/outer diameter of 2.5/4 mm. As a sliding stage, the ring-shaped neodymium magnet with an inner/outer diameter of 13/25 mm, thickness of 5 mm and an acrylic cylindrical reflector with an outer diameter of 7.5 mm and length of 9 mm that a steel ball with an 02002-p. 3 outer diameter of 5 mm were used. Figure 6 shows the construction and operating principle of the measuring system using the tested sensor.…”
Section: Flexible Displacement Sensor Using Flexible Tubementioning
confidence: 99%
“…Recently, pneumatic welfare systems to support a nursing care and a rehabilitation of the elderly and the disabled are actively researched and developed [1][2][3][4]. In the system, many wearable actuators such as a rubber artificial muscle have been used [5][6][7].…”
Section: Introductionmentioning
confidence: 99%
“…The rehabilitation devices using soft pneumatic actuators for disabled are actively researched and developed [2][3][4][5]. In the previous study, the wrist rehabilitation device using flexible robot arm that consists of three flexible pneumatic cylinders [6] was proposed and tested.…”
Section: Introductionmentioning
confidence: 99%
“…According to aging society and decreasing birth rate in Japan [1], the requirement using soft actuator for the rehabilitation device and power assisting devices is rapidly increasing [2][3][4][5]. As a soft actuator, a rubber artificial muscle is well-known and actively used because of its larger generated force.…”
Section: Introductionmentioning
confidence: 99%