2017
DOI: 10.1186/s12938-017-0412-1
|View full text |Cite
|
Sign up to set email alerts
|

STAMPS: development and verification of swallowing kinematic analysis software

Abstract: BackgroundSwallowing impairment is a common complication in various geriatric and neurodegenerative diseases. Swallowing kinematic analysis is essential to quantitatively evaluate the swallowing motion of the oropharyngeal structures. This study aims to develop a novel swallowing kinematic analysis software, called spatio-temporal analyzer for motion and physiologic study (STAMPS), and verify its validity and reliability.MethodsSTAMPS was developed in MATLAB, which is one of the most popular platforms for biom… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 11 publications
(10 citation statements)
references
References 11 publications
0
10
0
Order By: Relevance
“…To the authors' knowledge, the fully automatic detection of any kind of abnormality from VFSS images has never previously been attempted. Most previous studies have used obsolete semiautomated identification and/or tracking algorithms [12][13][14][15], in which salient landmarks must first be demarcated by humans. Two previous studies have attempted fully automated analysis of VFSS images, but did not address pathological findings.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To the authors' knowledge, the fully automatic detection of any kind of abnormality from VFSS images has never previously been attempted. Most previous studies have used obsolete semiautomated identification and/or tracking algorithms [12][13][14][15], in which salient landmarks must first be demarcated by humans. Two previous studies have attempted fully automated analysis of VFSS images, but did not address pathological findings.…”
Section: Discussionmentioning
confidence: 99%
“…Hossain et al attempted to track the motion of the hyoid bone semi-automatically by determining the region of interest using the Haar classifier, but manual identification of templates was required to increase accuracy [13]. Lee et al developed MATLAB-based software for kinematic analysis of swallowing with high correlation and reliability, but specific events and target structures should be marked manually [14]. Most existing models use automatic tracking of the salient anatomical structures following human manual demarcation in the first few frames.…”
Section: Introductionmentioning
confidence: 99%
“…The length of the VFSS videos ranged from approximately 2 to 5 seconds. Swallowing motion analysis software, called the spatio-temporal analyzer for motion and physiologic study (STAMPS; https://github.com/cmookj/stamps), was used to obtain positional data of the hyoid bone [17]. The position of the hyoid bone was determined by two experienced examiners who were blinded to the results of the developed algorithm.…”
Section: B Swallowing Assessmentmentioning
confidence: 99%
“…A more objective analysis of swallowing biomechanical events is VFSS overlaid with swallowing kinematic evaluation. This is also known to have excellent interrater and intrarater reliability 6 . VFSS has several disadvantages, however, including radiation exposure, altered food consistency and sensory feedback due to the use of contrast medium, and limited patient accessibility 7 .…”
Section: Introductionmentioning
confidence: 98%
“…Dysphagia is a critical clinical issue that can occur in various disease groups, including stroke, head and neck cancer, Parkinson’s disease, and motor neuron disease 1 4 . Aspiration resulting from compromised swallowing can lead to aspiration pneumonia, which increases mortality and negatively affects the quality of life of patients 5 , 6 .…”
Section: Introductionmentioning
confidence: 99%