2016
DOI: 10.1016/j.snb.2015.10.097
|View full text |Cite
|
Sign up to set email alerts
|

Staining-free cell viability measurement technique using lens-free shadow imaging platform

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 19 publications
0
11
0
Order By: Relevance
“…Similarly, a mean error of 3.4% and 13.7% was obtained for lymphocytes and monocytes, respectively ( Figure 5 b,c). Using the shadow parameters developed in this study, the average error rate for the classification of neutrophils, lymphocytes, and monocytes was better than that of our previously reported method ( Figure 5 g) [ 32 ]. Furthermore, the average correlation was 0.999, which was also much better than in the previous study.…”
Section: Resultsmentioning
confidence: 50%
See 1 more Smart Citation
“…Similarly, a mean error of 3.4% and 13.7% was obtained for lymphocytes and monocytes, respectively ( Figure 5 b,c). Using the shadow parameters developed in this study, the average error rate for the classification of neutrophils, lymphocytes, and monocytes was better than that of our previously reported method ( Figure 5 g) [ 32 ]. Furthermore, the average correlation was 0.999, which was also much better than in the previous study.…”
Section: Resultsmentioning
confidence: 50%
“…We have previously reported that heterogeneous solutions of erythrocytes, yeast cells, E. coli , and microparticles of different sizes can be characterized automatically without lenses or microscope objectives. LSIT can be used to determine hemoglobin concentration [ 29 , 30 ], analyze the growth of bacterial biofilms [ 31 ], and perform various cell counts [ 27 , 32 ]. LSIT has advantages such as compactness, low cost, and high throughput because it does not require structures for optical lenses and alignments [ 25 ].…”
Section: Introductionmentioning
confidence: 99%
“…When the projectile passes through the image surface, part of the parallel light is blocked, and a dark area forms on the image sensor. The boundary between the bright and dark areas is the projection of the projectile [24][25][26][27][28][29]. The position of the projection of the light screen and the position of the projectile on the image sensor are separately recorded by the high-speed camera [30][31][32], and the target deviation of the projectile can be obtained according to the pixel value of the image sensor.…”
Section: Principlementioning
confidence: 99%
“…Since this arrangement consists of a few components, most of which are easily available and at a low price, therefore it reduces the overall cost of the system [2]. This simple and cost-effective nature facilitates the feasibility of the LSIT for applications in the field of point-of-care systems or telemedicine systems [3,4,5]. Recent advancements in machine learning, especially deep learning, have facilitated many applications concerning medical diagnostics [6,7,8,9,10,11,12], and have been widely adopted in the field of microscopy [13,14,15].…”
Section: Introductionmentioning
confidence: 99%