Stacked Tantalum Cones as a Method for Treating Severe Distal Femoral Bone Deficiency in Total Knee Arthroplasty

Abstract: Severe bone loss in distal femur has traditionally been managed with bulk cementing, bone graft, metal augments, trabecular metal cones, and mega prosthesis. The authors present an alternative method using a stacked configuration of two tantalum cones to manage severe distal femoral bone loss. This study aims to evaluate the mid-term outcomes and possible complications in patients treated with this novel technique. We retrospectively analyzed the prospectively maintained records of 16 knees (in 16 patients) pr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0
2

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 20 publications
0
6
0
2
Order By: Relevance
“…Boureau et al used a two stacked cone technique in 7 cases of severe distal femoral defects without evidence of implant migration or loosening at a mean 17 months of follow-up [15]. Similarly, Rajgopal et al used a stacked cone technique in 16 cases of severe femoral metaphyseal bone loss in primary and revision TKAs [16]. At the end of a mean 57 months of follow-up, all implants were osseointegrated without radiolucencies [16].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Boureau et al used a two stacked cone technique in 7 cases of severe distal femoral defects without evidence of implant migration or loosening at a mean 17 months of follow-up [15]. Similarly, Rajgopal et al used a stacked cone technique in 16 cases of severe femoral metaphyseal bone loss in primary and revision TKAs [16]. At the end of a mean 57 months of follow-up, all implants were osseointegrated without radiolucencies [16].…”
Section: Discussionmentioning
confidence: 99%
“…Similarly, Rajgopal et al. used a stacked cone technique in 16 cases of severe femoral metaphyseal bone loss in primary and revision TKAs [ 16 ]. At the end of a mean 57 months of follow-up, all implants were osseointegrated without radiolucencies [ 16 ].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Однако на сегодняшний день отсутствуют отдаленные результаты использования подобных металлоконструкций [18,28]. К недостаткам двойных конусов можно отнести малую площадь контакта с нативной костью и высокую стоимость [29]. Кроме этого, для достижения первичной стабильности требуется выполнение дополнительных опилов и так уже скомпрометированной кости для формирования ложа имплантата [1].…”
Section: рис 1 рентгенограммы коленного сустава в прямой и боковой проекциях с установленным связанным имплантатом при поступлении в клинunclassified
“…Также использование конусов ограничено по формам и типоразмерам, что требует во время операции их тщательного подбора [1]. В случаях применения метода двойных конусов существует риск мальпозиции бедренного компонента ввиду сложности восстановления правильной ротации, а иногда и отсутствия возможности применения офсетных ножек [29]. При повторных операциях удаление данных компонентов достаточно затруднительно и может сопровождаться потерей костной массы [1].…”
Section: рис 1 рентгенограммы коленного сустава в прямой и боковой проекциях с установленным связанным имплантатом при поступлении в клинunclassified